PENNSVILLE, NJ ·
OSHA Inspection: GANES CHEMICAL
Accident-driven inspection · Health discipline
At a glance
On , OSHA opened an accident-driven health inspection of GANES CHEMICAL in 33 INDUSTRIAL PARK RD, PENNSVILLE, NJ 08070 (NAICS 000000). OSHA activity number 302714340.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GANES CHEMICAL
- Site address
- 33 INDUSTRIAL PARK RD
- City
- PENNSVILLE
- State
- NJ
- ZIP
- 08070
What kind of inspection was it?
- Inspection type
- Accident-driven (A)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- Union (Y)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 2834
- Employees
- 192
- Ownership type
- Private (A)
Citations
1 citation on file for this inspection.
5(a)(1)
- Issued
- Aug 22, 2000
- Abate by
- Oct 30, 2000
- Penalty
- Initial $3,500 · Current $2,100 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to: a flash fire which occurred while the employees were loading a drier with a material that contained heptane. a). Establishment (BLDG 1) - Employees who were loading a drier with a product which contained heptane, were exposed to a flash fire and received severe burns when the heptane vapors ignited. Engineering controls and work practices were not sufficient to prevent a flash fire from starting inside the drier, (re: NFPA 77, Static Electricity, Chap. 2). A feasible method of abatement includes, but is not limited to; 1) Installation of an independent measure of the nitrogen blanket in the drier to ensure the oxygen level is below that which will support combustion. 2). Investigate alternate means and methods of intermediate product packaging to minimize the potential for static discharge when handling these materials. 3). Provide physical chokes/rotary valves/fast acting dampers and valves to block any flame front that might be produced in the enclosure areas. 4). Provide explosion protection for all processes involving pouring/charging of flammable materials. NOTE:ABATEMENT DOCUMENTATION REQUIRED FOR THIS ITEM. See page 2,"Notification of Corrective Action" for instructions.
Recent events (2)
- · I (S) $2100.00
- · Z (S) $3500.00
More inspections in this industry (NAICS 000000)
More inspections in NJ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 302714340.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.