FORT COLLINS, CO ·
OSHA Inspection: STEELE'S MARKET
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of STEELE'S MARKET in 1001 E. HARMONY RD., FORT COLLINS, CO 80525 (NAICS 000000). OSHA activity number 302769146.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- STEELE'S MARKET
- Site address
- 1001 E. HARMONY RD.
- City
- FORT COLLINS
- State
- CO
- ZIP
- 80525
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (N)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 5411
- Employees
- 80
- Ownership type
- Private (A)
Citations
2 citations on file for this inspection.
5(a)(1)
- Issued
- Nov 2, 1999
- Abate by
- Nov 6, 1999
- Penalty
- Initial $1,125 · Current $1,125
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that: On or about October 23, 1999 (a) Employees were exposed to the hazard of over-exposure to low temperatures that could result in hypothermia. The walk-in freezer door in the grocery storage area could not be opened from inside the freezer. If the door closes behind an employee, the employee could become locked inside the freezer,resulting in the over exposure to low temperatures. One feasible and acceptable abatement method to correct this hazard is to install a door handle mechanism that complies with paragraph 5.4 of Underwriters Laboratories, Inc. Standard UL 471 (1987) which states: "Unless provided with other means of exit, door(s) intended for entrance of persons into the refrigerated compartment of a refrigerator shall be provided with a latch release mechanism that will open the door(s)from the inside by a force applied outwardly to the door or to a release actuator. If the latch is provided with a key lock, the latch release mechanism shall be constructed so that the lock can be opened from the interior. Abatement Note: Abatement certification and documentation are required for this item (See enclosed "Sample Abatement-Certification Letter").
1910.38 A01
- Issued
- Nov 1, 1999
- Abate by
- Dec 4, 1999
More inspections in this industry (NAICS 000000)
More inspections in CO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 302769146.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.