Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: GE MEDICAL SYSTEMS

Accident-driven inspection · Safety discipline

On , OSHA opened an accident-driven safety inspection of GE MEDICAL SYSTEMS in 525 E 70 STREET, NEW YORK, NY 10021 (NAICS 000000). OSHA activity number 302942594.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch GE Medical Systems — free Get an email when a new federal OSHA severe-injury report for GE Medical Systems is published. One employer, no account, unsubscribe in one click.
Establishment
GE MEDICAL SYSTEMS
Site address
525 E 70 STREET
City
NEW YORK
State
NY
ZIP
10021
Mailing
1979 MARCUS AVE, SUITE E-137, LAKE SUCCESS, NY 11042
Inspection type
Accident-driven (A)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Y
Opened
Closing conference
Case closed
Data loaded
NAICS code
000000
SIC code (legacy)
3845
Employees
3000
Ownership type
A

3 citations on file for this inspection.

5(a)(1)

Deleted Serious Gravity 10 1 instance 4 exposed
Issued
Feb 20, 2001
Abate by
Feb 23, 2001
Penalty
Initial $4,500 · Current $4,500
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees in that employees
were exposed to: Oxygen deficient atmosphere from cryogenic Nitrogen
releasing into enclosed
area.
a)MRI installation site at 525 E 70th Street.
Employees involved in cooling the MRI magnet with cryogenic Nitrogen were
exposed to an Oxygen deficient atmosphere because they did not establish or
implement any control measures or means to ensure that Oxygen deficiency or
displacement was not occurring in the work area, on or about 9/20/00.
Among other methods, feasible and acceptable means of abatement are:
Follow the existing MRI
magnet cooling procedures and control methods which are established and
utilized at GE`s fixed
facility which includes: Provide continuous oxygen monitoring; Provide
adequate air movement
and ventilation to prevent oxygen deficient atmospheres under 19.5by
using exhaust or floor
fans; Provide training to employees as to the properties and safe handling
of cryogenic Nitrogen.
(ie. It is heavier than air, odorless, colorless, can asphyxiate in
seconds without warning, etc..)
Additional references which contain useful abatement information includes:
The Manufacturer`s
Safetygram #17, Dangers of Oxygen Deficient Atmospheres; The Material
Safety Data Sheet;
Compressed Gas Association (CGA) pamphlet P-14 1992 Paragraph 6; and CGA
Pamphlet P-12
Safe Handling and Storage of Cryogenic Liquids.
Recent events (2)
  • — F (S) $4500.00
  • — Z (S) $4500.00

1910.132 A

Other-than-serious Gravity 10 1 instance 4 exposed
Issued
Feb 20, 2001
Abate by
Mar 25, 2001
Penalty
Initial $4,500 · Current $5,625
Recent events (2)
  • — F (O) $5625.00
  • — Z (S) $4500.00

1910.134 D02 I

Deleted Serious Gravity 03 1 instance 4 exposed
Issued
Feb 20, 2001
Abate by
Feb 23, 2001
Penalty
Initial $2,250 · Current $2,250
Recent events (2)
  • — F (S) $2250.00
  • — Z (S) $2250.00

View GE Medical Systems's full OSHA safety record →