NEW YORK, NY —
OSHA Inspection: GE MEDICAL SYSTEMS
Accident-driven inspection · Safety discipline
At a glance
On , OSHA opened an accident-driven safety inspection of GE MEDICAL SYSTEMS in 525 E 70 STREET, NEW YORK, NY 10021 (NAICS 000000). OSHA activity number 302942594.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GE MEDICAL SYSTEMS
- Site address
- 525 E 70 STREET
- City
- NEW YORK
- State
- NY
- ZIP
- 10021
- Mailing
- 1979 MARCUS AVE, SUITE E-137, LAKE SUCCESS, NY 11042
What kind of inspection was it?
- Inspection type
- Accident-driven (A)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Y
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 3845
- Employees
- 3000
- Ownership type
- A
Citations
3 citations on file for this inspection.
5(a)(1)
- Issued
- Feb 20, 2001
- Abate by
- Feb 23, 2001
- Penalty
- Initial $4,500 · Current $4,500
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to: Oxygen deficient atmosphere from cryogenic Nitrogen releasing into enclosed area. a)MRI installation site at 525 E 70th Street. Employees involved in cooling the MRI magnet with cryogenic Nitrogen were exposed to an Oxygen deficient atmosphere because they did not establish or implement any control measures or means to ensure that Oxygen deficiency or displacement was not occurring in the work area, on or about 9/20/00. Among other methods, feasible and acceptable means of abatement are: Follow the existing MRI magnet cooling procedures and control methods which are established and utilized at GE`s fixed facility which includes: Provide continuous oxygen monitoring; Provide adequate air movement and ventilation to prevent oxygen deficient atmospheres under 19.5by using exhaust or floor fans; Provide training to employees as to the properties and safe handling of cryogenic Nitrogen. (ie. It is heavier than air, odorless, colorless, can asphyxiate in seconds without warning, etc..) Additional references which contain useful abatement information includes: The Manufacturer`s Safetygram #17, Dangers of Oxygen Deficient Atmospheres; The Material Safety Data Sheet; Compressed Gas Association (CGA) pamphlet P-14 1992 Paragraph 6; and CGA Pamphlet P-12 Safe Handling and Storage of Cryogenic Liquids.
Recent events (2)
- — F (S) $4500.00
- — Z (S) $4500.00
1910.132 A
- Issued
- Feb 20, 2001
- Abate by
- Mar 25, 2001
- Penalty
- Initial $4,500 · Current $5,625
Recent events (2)
- — F (O) $5625.00
- — Z (S) $4500.00
1910.134 D02 I
- Issued
- Feb 20, 2001
- Abate by
- Feb 23, 2001
- Penalty
- Initial $2,250 · Current $2,250
Recent events (2)
- — F (S) $2250.00
- — Z (S) $2250.00
More inspections at GE Medical Systems
View GE Medical Systems's full OSHA safety record →
More inspections in this industry (NAICS 000000)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 302942594.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.