FAIRFAX, VA ·
OSHA Inspection: S. HAMILL BUILDING SERVICES
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of S. HAMILL BUILDING SERVICES in 12601 FAIR LAKES CIRCLE, FAIRFAX, VA 22033 (NAICS 000000). OSHA activity number 303091110.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- S. HAMILL BUILDING SERVICES
- Site address
- 12601 FAIR LAKES CIRCLE
- City
- FAIRFAX
- State
- VA
- ZIP
- 22033
- Mailing
- 2204 WASHINGTON AVENUE, #203, SILVER SPRING, MD 20910
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (N)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 1799
- Employees
- 3
- Ownership type
- Private (A)
- Industry flags
- Construction safety.
Citations
2 citations on file for this inspection.
510001 A
- Issued
- Mar 5, 2002
- Abate by
- Apr 7, 2002
- Penalty
- Initial $750 · Current $450 Reduced
General-duty citation text
Title 40.1-51.1.(a), Code of Virginia: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that: (a) 110' fall hazard. At 7:10 AM on 02/25/02 on the north side of 12601 Fair Lakes Circle, Fairfax, Virginia, the employer was having an employee use a Sky Genie brand lowering device in lieu of a boatswains' chair to power wash the building which resulted in an employee falling 110' feet and breaking his leg. Lowering devices are classified as prohibited equipment under paragraph 11.3 of ASME/ANSI A39.1a-1987, Safety Requirements For Window Cleaning. "One feasible and acceptable abatement method, among others, to correct this hazard is to use an approved boatswains' chair or suspension scaffold to power wash the side of the building."
Recent events (2)
- · I (S) $450.00
- · Z (S) $750.00
1926.451 G01 VII
- Issued
- Mar 5, 2002
- Abate by
- Apr 7, 2002
More inspections in this industry (NAICS 000000)
More inspections in VA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 303091110.