CHICAGO, IL ·
OSHA Inspection: EL RINCON SUPPORTIVE SERVICES ORGANIZATION
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of EL RINCON SUPPORTIVE SERVICES ORGANIZATION in 1874 N MILWAUKEE, CHICAGO, IL 60647 (NAICS 000000). OSHA activity number 303138077.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- EL RINCON SUPPORTIVE SERVICES ORGANIZATION
- Site address
- 1874 N MILWAUKEE
- City
- CHICAGO
- State
- IL
- ZIP
- 60647
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 8069
- Employees
- 41
- Ownership type
- A
Citations
11 citations on file for this inspection.
5(a)(1)
- Issued
- Sep 28, 2000
- Abate by
- Nov 16, 2000
- Penalty
- Initial $875 · Current $438 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazard of being infected with Mycobacterium tuberculosis through unprotected contact with clients who were infectious or suspected to be infectious with tuberculosis in that: a. El Rincon did not implement a maintenance schedule for the ventilation controls at the Clinic, i.e., change procedures and schedule for replacing and inspecting HEPA filters used in the recirculating air system at the Clinic. b. El Rincon did not implement a maintenance schedule for the ultraviolet lights used in the Clinic, i.e., develop a procedure for their cleaning, inspection, and replacement. c. El Rincon did not screen clients for active tuberculosis during "intake" processing with counselors. Feasible and useful abatement methods for reducing this hazard, as recommended by the CDC, include, but are not limited to: (a) Develop and implement a protocol which includes criteria for change schedules and procedures for the maintenance of engineering controls, such as, the ventilation system HEPA filters and the ultraviolet lights to maintain "as-installed" effectiveness and shall include a recognized field test method, an acceptance criteria, frequencies and warning labelling of the duct work and the ultraviolet lights. (b) Develop a tuberculosis screening checklist for the Intake Coordinator to complete at the beginning of the initial interview that would require further action if there was an indication of active tuberculosis. Abatement documentation only is required for this item in accordance with the requirement of 29 CFR 1903.19(d).
Recent events (2)
- · I (S) $437.50
- · Z (S) $875.00
1910.1030 C01 I
- Issued
- Sep 28, 2000
- Abate by
- Nov 16, 2000
- Penalty
- Initial $2,500 · Current $1,250 Reduced
Recent events (2)
- · I (S) $1250.00
- · Z (S) $2500.00
1910.1030 D02 I
- Issued
- Sep 28, 2000
- Abate by
- Jan 2, 2001
1910.1030 D04 IIA
- Issued
- Sep 28, 2000
- Abate by
- Oct 2, 2000
1910.1030 F02 I
- Issued
- Sep 28, 2000
- Abate by
- Nov 14, 2000
1910.1030 G02 I
- Issued
- Sep 28, 2000
- Abate by
- Jan 17, 2001
Recent events (2)
- · P (S)
- · Z (S)
1904.2 A
- Issued
- Sep 28, 2000
- Abate by
- Oct 18, 2000
- Penalty
- Initial $500 · Current $250 Reduced
Recent events (2)
- · I (O) $250.00
- · Z (O) $500.00
1910.1020 G01 I
- Issued
- Sep 28, 2000
- Abate by
- Oct 23, 2000
1910.1020 G01 II
- Issued
- Sep 28, 2000
- Abate by
- Oct 23, 2000
1910.1020 G01 III
- Issued
- Sep 28, 2000
- Abate by
- Oct 23, 2000
1910.1200 E01
- Issued
- Sep 28, 2000
- Abate by
- Jan 17, 2001
Recent events (2)
- · P (O)
- · Z (O)
More inspections in this industry (NAICS 000000)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 303138077.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.