SPRINGFIELD, MO —
OSHA Inspection: COX AIR SYSTEMS, INC.
Accident-driven inspection · Safety discipline
At a glance
On , OSHA opened an accident-driven safety inspection of COX AIR SYSTEMS, INC. in 4500 PROGRESS PLACE, SPRINGFIELD, MO 65803 (NAICS 000000). OSHA activity number 303211171.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- COX AIR SYSTEMS, INC.
- Site address
- 4500 PROGRESS PLACE
- City
- SPRINGFIELD
- State
- MO
- ZIP
- 65803
- Mailing
- 127 WILBUR PARRISH CIRCLE, BELTON, MO 64012
What kind of inspection was it?
- Inspection type
- Accident-driven (A)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Y
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 1711
- Employees
- 27
- Ownership type
- A
- Industry flags
- Construction safety.
Citations
4 citations on file for this inspection.
5(a)(1)
- Issued
- Apr 9, 2001
- Abate by
- Apr 23, 2001
- Penalty
- Initial $3,500 · Current $3,500
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in the form of being struck by falling materials in that employees were exposed to: (a)Job Site at 4500 Progress Place, Springfield Missouri - On or about January 5, 2001, Nylon slings were being used to hoist a dust collection fan unit with slings rigged with a choker and attached around sharp edges on the fan unit without protective pads installed to prevent cut through. Among other methods, recognized and feasible means of abatement to correct this hazard include, but are not limited to: Use a shakle or padding at the three connection end on the fan unit when lifting or moving the dust collection fan unit to prevent damage such as cutting or tearing, as required by the American Society of Mechanical Engineers (ASME) standard B30.9 (Slings), & section 9-9.5, Operating Practices paragraph (g). Note: Abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, other written records.
1926.100 A
- Issued
- Apr 9, 2001
- Abate by
- Apr 20, 2001
- Penalty
- Initial $1,750 · Current $1,750
1926.550 A19
- Issued
- Apr 9, 2001
- Abate by
- Apr 23, 2001
- Penalty
- Initial $1,750 · Current $875 Reduced
Recent events (2)
- — I (S) $875.00
- — Z (S) $1750.00
1926.21 B02
- Issued
- Apr 9, 2001
- Abate by
- Apr 23, 2001
- Penalty
- Initial $500
Recent events (2)
- — I (O)
- — Z (O) $500.00
More inspections at COX AIR Systems, INC.
View COX AIR Systems, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 000000)
More inspections in MO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 303211171.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.