MUNDELEIN, IL —
OSHA Inspection: HUFFCO, INC. DBA ZIEBART TIDY CAR
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of HUFFCO, INC. DBA ZIEBART TIDY CAR in 825 E. HWY. 45, MUNDELEIN, IL 60060 (NAICS 000000). OSHA activity number 303263354.
Where did this inspection happen?
- Establishment
- HUFFCO, INC. DBA ZIEBART TIDY CAR
- Site address
- 825 E. HWY. 45
- City
- MUNDELEIN
- State
- IL
- ZIP
- 60060
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 7549
- Employees
- 4
- Ownership type
- A
Citations
10 citations on file for this inspection.
5(a)(1)
- Issued
- May 23, 2000
- Abate by
- Jul 11, 2000
- Penalty
- Initial $600 · Current $600
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazard(s) being struck and/or crushed by a vehicle due to collapse or failure of the vehicle lift: a) Huffco, Inc. dba Ziebart Tidy Car - In the Undercoating Spray Area one employee worked under a Weaver Twin Post Automotive Lift while performing his undercoating duties. The employer failed to maintain and care for the lift to ensure its continued safe operation. The top mounting screw on one lift lock was cracked off. The lift was leaking hydraulic oil on the floor directly below the lifting cylinders. The low oil shut off was not operable because the low oil float was missing. Among others, one feasible method of abatement would be to maintain the automotive lift(s) in accordance with the requirements of ANSI B153.1-1990. Including, but not limited to the correcting the following deficiencies noted on the lifts: 1. Replace the Tube and Plunger gaskets on both cylinders. 2. Install a Low Oil Shut Off Float. 3. Replace the cracked capscrew with a new screw. 4. Ensure oil level is at 60 gallons. Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).s
1910.134 C01
- Issued
- May 23, 2000
- Abate by
- Jul 11, 2000
- Penalty
- Initial $600 · Current $600
1910.134 D01 II
- Issued
- May 23, 2000
- Abate by
- Jul 11, 2000
1910.134 E01
- Issued
- May 23, 2000
- Abate by
- Jul 11, 2000
1910.134 H02 I
- Issued
- May 23, 2000
- Abate by
- May 26, 2000
1910.134 K01
- Issued
- May 23, 2000
- Abate by
- Jul 11, 2000
1910.304 F04
- Issued
- May 23, 2000
- Abate by
- Jun 7, 2000
- Penalty
- Initial $750 · Current $750
1910.1000 A01
- Issued
- May 23, 2000
- Abate by
- Jul 11, 2000
- Penalty
- Initial $600 · Current $600
1073
1910.1000 E
- Issued
- May 23, 2000
- Abate by
- Jul 11, 2000
1073
1910.107 B08
- Issued
- May 23, 2000
- Abate by
- May 26, 2000
More inspections in this industry (NAICS 000000)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 303263354.