OSHA Inspection: CTSP CORP.

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of CTSP CORP. in 279 HOMESTEAD RD., BELLE-MEAD, NJ 08502 (NAICS 000000). OSHA activity number 303283345.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Ctsp Corp. — free Get an email when a new federal OSHA severe-injury report for Ctsp Corp. is published. One employer, no account, unsubscribe in one click.
Establishment
CTSP CORP.
Site address
279 HOMESTEAD RD.
City
BELLE-MEAD
State
NJ
ZIP
08502
Mailing
279 HOMESTEAD RD., BELLE MEAD, NJ 08502
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Data loaded
NAICS code
000000
SIC code (legacy)
3087
Employees
70
Ownership type
A

1 citation on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 4 exposed
Issued
Apr 10, 2001
Abate by
Apr 13, 2001
Penalty
Initial $5,000 · Current $3,500 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized
hazards that
were causing or likely to cause death or serious physical harm to
employees in that employees
were exposed to an oxygen-deficient atmosphere:
a- Room 12: A nitrogen delivery system used to inert equipment such as jet
mills, was
installed in room 12 and was enabled for use.  This system could create an
oxygen-
deficient atmosphere within the room.  Employee(s) who may enter this room
could be
asphyxiated due to high levels of nitrogen.  Condition noted on or about
3/7/01.
Among other methods, feasible and useful methods to correct this hazard
include, but are
not limited to, incorporating a monitoring device that would warn of an
oxygen deficient
atmosphere within the room, placing warning devices from monitoring
systems both
inside and outside the room, placarding the room where oxygen deficient
atmospheres
may exist and appropriately marking nitrogen valves used on the
distribution
system so
there is no confusion over the purpose of each valve.