WHITEVILLE, NC —
OSHA Inspection: W & W ELECTRIC MOTOR SHOP, INC.
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of W & W ELECTRIC MOTOR SHOP, INC. in 5240 JAMES B. WHITE HWY. SOUTH, WHITEVILLE, NC 28472 (NAICS 000000). OSHA activity number 303331326.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- W & W ELECTRIC MOTOR SHOP, INC.
- Site address
- 5240 JAMES B. WHITE HWY. SOUTH
- City
- WHITEVILLE
- State
- NC
- ZIP
- 28472
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 7694
- Employees
- 6
- Ownership type
- A
- Industry flags
- Manufacturing health.
Citations
21 citations on file for this inspection.
95012901
- Issued
- May 17, 2000
- Abate by
- Jun 4, 2000
- Penalty
- Initial $125 · Current $100 Reduced
General-duty citation text
North Carolina General Statute 95-129(1) of the Occupational Safety and Health Act of North Carolina: The employer did not furnish to each of his employees conditions of employment and a place of employment free from recognized hazards that were causing or likely to cause death or serious physical harm to employees, in that employees were exposed to falling overhead loads: a)facility, shop, loading/unloading area - employees were allowed to stand in close proximity of and reach underneath hoisted loads, i.e., electric motors, of overhead hoists and appurtenance that were not load rated. Employees used several chain hoist such as but not limited to a CM Valustar 2-tons, Load Star 2- tons, Kohnezuc 7.5-tons, and a CM 3-tons chain hoists that were used to hoist loads, i.e., electric motors, to perform loading and unloading activities. One feasible and acceptable abatement method, among others, to correct this hazard is to load rate the hoists and appurtenances to ensure that they can withstand the rated load capacity. (Reference: American Society of Mechanical Engineers, for Overhead Hoists (Underhung), ASME B30.16-1993, Chapter 16-1 (Marking, Construction, and Installation), Section 16-1.2 (Construction), Section 16-1.2.1(a) (Mechanical Design):
Recent events (2)
- — I (S) $100.00
- — Z (S) $125.00
1910.178 L01 I
- Issued
- May 17, 2000
- Abate by
- Jun 19, 2000
- Penalty
- Initial $175 · Current $130 Reduced
Recent events (2)
- — I (S) $130.00
- — Z (S) $175.00
1910.178 Q01
- Issued
- May 17, 2000
- Abate by
- Jun 4, 2000
Recent events (2)
- — I (S)
- — Z (S)
1910.178 Q07
- Issued
- May 17, 2000
- Abate by
- Jun 4, 2000
Recent events (2)
- — I (S)
- — Z (S)
1910.212 A01
- Issued
- May 17, 2000
- Abate by
- Jun 4, 2000
- Penalty
- Initial $125 · Current $100 Reduced
Recent events (2)
- — I (S) $100.00
- — Z (S) $125.00
1910.212 B
- Issued
- May 17, 2000
- Abate by
- Jun 4, 2000
Recent events (2)
- — I (S)
- — Z (S)
1910.242 B
- Issued
- May 17, 2000
- Abate by
- Jun 4, 2000
- Penalty
- Initial $175 · Current $130 Reduced
Recent events (2)
- — I (S) $130.00
- — Z (S) $175.00
1910.243 C03
- Issued
- May 17, 2000
- Abate by
- Jun 4, 2000
- Penalty
- Initial $100 · Current $100
Recent events (2)
- — I (S) $100.00
- — Z (S) $100.00
7F0102
- Issued
- May 17, 2000
- Abate by
- May 22, 2000
1910.145 F03
- Issued
- May 17, 2000
- Abate by
- Jun 4, 2000
1910.157 G01
- Issued
- May 17, 2000
- Abate by
- Jun 19, 2000
1910.184 D
- Issued
- May 17, 2000
- Abate by
- Jun 4, 2000
1910.303 F
- Issued
- May 17, 2000
- Abate by
- Jun 4, 2000
1910.305 G01 I
- Issued
- May 17, 2000
- Abate by
- Jun 4, 2000
1910.138 A
- Issued
- May 17, 2000
- Abate by
- Jun 19, 2000
1910.132 D02
- Issued
- May 17, 2000
- Abate by
- Jun 19, 2000
1910.1200 E01
- Issued
- May 17, 2000
- Abate by
- Jun 19, 2000
1910.1200 F05 I
- Issued
- May 17, 2000
- Abate by
- Jun 4, 2000
1910.1200 F05 II
- Issued
- May 17, 2000
- Abate by
- Jun 4, 2000
1910.1200 G01
- Issued
- May 17, 2000
- Abate by
- Jun 4, 2000
1910.1200 H01
- Issued
- May 17, 2000
- Abate by
- Jun 19, 2000
More inspections in this industry (NAICS 000000)