OSHA Inspection: GFC FOAM LLC

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of GFC FOAM LLC in 25 JAYCEE DRIVE, WEST HAZLETON, PA 18201 (NAICS 000000). OSHA activity number 303340400.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch GFC Foam LLC — free Get an email when a new federal OSHA severe-injury report for GFC Foam LLC is published. One employer, no account, unsubscribe in one click.
Establishment
GFC FOAM LLC
Site address
25 JAYCEE DRIVE
City
WEST HAZLETON
State
PA
ZIP
18201
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
Y
Opened
Closing conference
Case closed
Data loaded
NAICS code
000000
SIC code (legacy)
3086
Employees
200
Ownership type
A

1 citation on file for this inspection.

5(a)(1)

Other-than-serious Gravity 03 1 instance 10 exposed
Issued
Nov 16, 2000
Abate by
Mar 31, 2001
Penalty
Initial $2,125 · Current $800 Reduced

Hazardous substances 8420X1001410

Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not
furnish employment and a place of employment which were free from
recognized hazards
that were causing or likely to cause death or serious physical harm to
employees in that
employees were exposed to fire and explosion hazards from the foam
reticulation process.
a) Reticulation process: The Joyce 540 thermal reticulation chamber,
pressure
relief devices, and appurtenances were not inspected, tested, and
maintained in
accordance with the National Board Inspection Code, ANSI / NB-23.
b) Reticulation process: The hydrogen feed piping system of the Joyce 540
thermal reticulation chamber, was  not inspected, tested, and maintained in
accordance with the Compressed Gas Association,  Standard for Hydrogen
Piping Systems at Consumer Locations, CGA G-5.4.
c) Reticulation process: The oxygen feed piping system of the Joyce 540
thermal reticulation chamber, was  not inspected, tested, and maintained in
accordance with the Compressed Gas Association,  Industrial Practices for
Gaseous Oxygen Transmission and Distribution Piping Systems, CGA G-4.4.
"ABATEMENT CERTIFICATION AND DOCUMENTATION REQUIRED"
AMONG OTHER METHODS,  FEASIBLE AND ACCEPTABLE
ABATEMENT METHODS TO CORRECT THESE HAZARDS ARE:
1) Inspect, test, and maintain the Reticulation Process equipment
per the referenced standards and codes.
2) Reference American Petroleum Institute,  Piping Inspection
Code, API 570, which offers additional guidance in hydrogen
and oxygen service.
3) Reticulator operators should be trained in hazard recognition,
evaluation, and control per  API 570,  1.4.5.
Recent events (2)
  • — I (O) $800.00
  • — Z (S) $2125.00

View GFC Foam LLC's full OSHA safety record →