OSHA Inspection: PIKE ELECTRIC, INC.

Accident-driven inspection · Safety discipline

On , OSHA opened an accident-driven safety inspection of PIKE ELECTRIC, INC. in KENSINGTON TRACE, LITHONIA, GA 30350 (NAICS 000000). OSHA activity number 303381925.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Pike Electric, INC. — free Get an email when a new federal OSHA severe-injury report for Pike Electric, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
PIKE ELECTRIC, INC.
Site address
KENSINGTON TRACE
City
LITHONIA
State
GA
ZIP
30350
Mailing
100 PIKE WAY, MOUNT AIRY, NC 27030
Inspection type
Accident-driven (A)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
000000
SIC code (legacy)
1623
Employees
3800
Ownership type
A

13 citations on file for this inspection.

5(a)(1)

Deleted Serious Gravity 03 1 instance 8 exposed
Issued
Mar 5, 2001
Abate by
Mar 19, 2001
Penalty
Initial $2,500
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees in that employees
were exposed to: Electrical burns and shock from high voltage of 14,400
volts.
At the jobsite on Sharon Church Road, on or about 10-17-2000; during
stringing operations,
employees were exposed to electrical shock hazards with voltages of 14,400
vots to ground and
24,400 volts phase to phase as the puller operator was not at the control
station during the
stringing operation. The operator could not make immediate adjustments to
the equipment in the
event of a snag, or slow the equipment down to prevent materials and
equipment from becoming
energized.
NOTE: Among other methods, one feasible and acceptable method to correct
this hazard is to
ensure that the operator remains at the operator control station while the
puller is operation.
Recent events (2)
  • — F (S)
  • — Z (S) $2500.00

1926.21 B02

Deleted Serious Gravity 10 23 instances 8 exposed
Issued
Mar 5, 2001
Abate by
Mar 29, 2001
Penalty
Initial $7,000
Recent events (2)
  • — F (S)
  • — Z (S) $7000.00

1926.307 D01

Deleted Serious Gravity 03 1 instance 7 exposed
Issued
Mar 5, 2001
Abate by
Mar 29, 2001
Penalty
Initial $2,500
Recent events (2)
  • — F (S)
  • — Z (S) $2500.00

1926.307 E03

Deleted Serious Gravity 03 1 instance 7 exposed
Issued
Mar 5, 2001
Abate by
Mar 29, 2001
Recent events (2)
  • — F (S)
  • — Z (S)

1926.307 F01

Deleted Serious Gravity 03 1 instance 7 exposed
Issued
Mar 5, 2001
Abate by
Mar 29, 2001
Recent events (2)
  • — F (S)
  • — Z (S)

1926.950 B01

Serious Gravity 10 1 instance 7 exposed
Issued
Mar 5, 2001
Abate by
Mar 29, 2001
Penalty
Initial $7,000 · Current $7,000
Recent events (2)
  • — F (S) $7000.00
  • — Z (S) $7000.00

1926.950 C01 I

Deleted Serious Gravity 10 1 instance 7 exposed
Issued
Mar 5, 2001
Abate by
Mar 29, 2001
Penalty
Initial $7,000
Recent events (2)
  • — F (S)
  • — Z (S) $7000.00

1926.950 C02 I

Deleted Serious Gravity 10 4 instances 7 exposed
Issued
Mar 5, 2001
Abate by
Mar 29, 2001
Penalty
Initial $7,000
Recent events (2)
  • — F (S)
  • — Z (S) $7000.00

1926.951 D01

Deleted Serious Gravity 10 1 instance 7 exposed
Issued
Mar 5, 2001
Abate by
Mar 29, 2001
Penalty
Initial $7,000
Recent events (2)
  • — F (S)
  • — Z (S) $7000.00

1926.951 D02

Deleted Serious Gravity 10 1 instance 3 exposed
Issued
Mar 5, 2001
Abate by
Mar 29, 2001
Recent events (2)
  • — F (S)
  • — Z (S)

1926.954 J

Serious Gravity 10 1 instance 14 exposed
Issued
Mar 5, 2001
Abate by
Mar 29, 2001
Penalty
Initial $7,000 · Current $1,000 Reduced
Recent events (2)
  • — F (S) $1000.00
  • — Z (S) $7000.00

1926.955 C02

Deleted Serious Gravity 10 6 instances 7 exposed
Issued
Mar 5, 2001
Abate by
Mar 29, 2001
Penalty
Initial $7,000
Recent events (2)
  • — F (S)
  • — Z (S) $7000.00

1926.955 D03

Deleted Serious Gravity 10 1 instance 7 exposed
Issued
Mar 5, 2001
Abate by
Mar 29, 2001
Penalty
Initial $7,000
Recent events (2)
  • — F (S)
  • — Z (S) $7000.00

View Pike Electric, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 303381925.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.