Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,196,249Inspections Most recent open 2026-08-20 Last loaded 2026-08-24

OSHA Inspection: COMMERCIAL DUCT BOARD SYSTEMS, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of COMMERCIAL DUCT BOARD SYSTEMS, INC. in 1100 TUCKASEEGEE ROAD, CHARLOTTE, NC 28208 (NAICS 000000). OSHA activity number 303399992.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Commercial Duct Board Systems, INC. for free Get an email when a new federal OSHA severe-injury report for Commercial Duct Board Systems, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1100 TUCKASEEGEE ROAD
City
CHARLOTTE
State
NC
ZIP
28208
Mailing
808 TUCKASEEGEE ROAD, CHARLOTTE, NC 28208
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (N)
Opened
Closing conference
Case closed
Data loaded
NAICS code
000000
SIC code (legacy)
3444
Employees
7
Ownership type
Private (A)
Industry flags
Manufacturing safety.

3 citations on file for this inspection.

95012901

Serious Gravity 02 1 instance 1 exposed
Issued
Sep 13, 2001
Abate by
Oct 6, 2001
Penalty
Initial $100 · Current $100
North Carolina General Statute 95-129(1) of the Occupational Safety
and Health Act of North Carolina:  The employer did not furnish
employment and a place of employment which were free from
recognized hazards that were causing or likely to cause death or
serious physical harm to employees in that employees were exposed
to:
Ref:ANSI B30.11-2.2.2  Rated Load Test
(a)coil line -- underhung crane had not been load tested
prior to initial use.
Note: Among other methods, one feasible and
acceptable abatement method to correct this
hazard is to have the crane load tested.

95012901

Serious Gravity 02 1 instance 1 exposed
Issued
Sep 13, 2001
Abate by
Oct 6, 2001
Penalty
Initial $100 · Current $100
North Carolina General Statute 95-129(1) of the Occupational Safety
and Health Act of North Carolina:  The employer did not furnish
employment and a place of employment which were free from
recognized hazards that were causing or likely to cause death or
serious physical harm to employees in that employees were exposed
to:
Ref:ANSI B30.20-1.4.2  Rated Load Test
(a)coil line -- spreader bar used with the underhung crane
had not been load tested.ng

1910.36 D01

Other-than-serious Gravity 01 1 instance 1 exposed
Issued
Sep 13, 2001
Abate by
Sep 19, 2001

View Commercial Duct Board Systems, INC.'s full OSHA safety record →