DECATUR, AL —
OSHA Inspection: FLUOR GLOBAL SERVICES
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of FLUOR GLOBAL SERVICES in 1002 5TH AVE. SE, DECATUR, AL 35601 (NAICS 000000). OSHA activity number 303431985.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FLUOR GLOBAL SERVICES
- Site address
- 1002 5TH AVE. SE
- City
- DECATUR
- State
- AL
- ZIP
- 35601
- Mailing
- 100 FLUOR DANIEL DR. C303A, GREENVILLE, SC 29607
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 7699
- Employees
- 220
- Ownership type
- A
- Industry flags
- Manufacturing safety.
Citations
1 citation on file for this inspection.
5(a)(1)
- Issued
- Mar 5, 2002
- Abate by
- Mar 11, 2002
- Penalty
- Initial $7,000 · Current $7,000
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazard of being crushed by a falling load from a chain hoist: (a) On or about September 19, 2001 at the number two coker located at the Solutia Inc. plant in Decatur AL employees were attempting to position a large boiler tube sheet with the use of Jet L-90 two ton overhead chain hoists. The chain hoist load line on the east end was passed through one of the 180 degree tubes and the hook was hooked back to the load line therefore using the chain of the hoist as a sling around the load to lift it. In addition a come along was hooked to the load line of the hoist to move the load laterally. Both the Jet L-90 operators manual and A.N.S.I. B30.16 prohibit this practice. "AMONG OTHER METHODS, ONE FEASIBLE AND ACCEPTABLE ABATEMENT METHOD TO CORRECT THIS HAZARD IS TO USE AN APPROVED LIFTING SLING OR DEVICE".
Recent events (2)
- — I (U) $7000.00
- — Z (S) $7000.00
More inspections at Fluor Global Services
View Fluor Global Services's full OSHA safety record →
More inspections in this industry (NAICS 000000)
More inspections in AL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 303431985.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.