MEDFORD, OK ·
OSHA Inspection: P.W. DRILLING LLC
Accident-driven inspection · Safety discipline
At a glance
On , OSHA opened an accident-driven safety inspection of P.W. DRILLING LLC in OFF HWY 81,8 MI. N OF CITY, MEDFORD, OK 73759 (NAICS 000000). OSHA activity number 303642003.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- P.W. DRILLING LLC
- Site address
- OFF HWY 81,8 MI. N OF CITY
- City
- MEDFORD
- State
- OK
- ZIP
- 73759
- Mailing
- P.O. BOX 320, CRESCENT, OK 73028
What kind of inspection was it?
- Inspection type
- Accident-driven (A)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (N)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 1381
- Employees
- 8
- Ownership type
- Private (A)
Citations
2 citations on file for this inspection.
5(a)(1)
- Issued
- Jul 11, 2001
- Abate by
- Jul 15, 2001
- Penalty
- Initial $1,500
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm: a)On March 15, 2001, a derrick hand was fatally injured when he fell approximately 108 feet with the derrick after guywire anchors "deadman" pulled loose causing the derrick to collapse. The employer id not protect employee(s) from recognized hazards of possible derrick collapse by verified anchor capacity before attaching guywires to the anchors. b)On March 15, 2001, a derrick hand was fatally injured when he fell approximately 108 feet with the derrick after guywire anchors "deadman" pulled loose causing the derrick to collapse. The employer did not protect employee(s) from the recognized hazard of possible derrick collapse by inspecting ground conditions around the anchors that might indicate reduced anchor capacity. ***Certification and Documentation of Abatement Required***on
Recent events (2)
- · F (S)
- · Z (S) $1500.00
1910.36 B02
- Issued
- Jul 11, 2001
- Abate by
- Jul 15, 2001
- Penalty
- Initial $1,500 · Current $1,500
Recent events (2)
- · F (S) $1500.00
- · Z (S) $1500.00
More inspections in this industry (NAICS 000000)
More inspections in OK
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 303642003.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.