ERIE, PA —
OSHA Inspection: ZURN INDUSTRIES, INC. - CAST METALS DIVISION
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of ZURN INDUSTRIES, INC. - CAST METALS DIVISION in 1301 RASPBERRY STREET, ERIE, PA 16502 (NAICS 000000). OSHA activity number 303709018.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ZURN INDUSTRIES, INC. - CAST METALS DIVISION
- Site address
- 1301 RASPBERRY STREET
- City
- ERIE
- State
- PA
- ZIP
- 16502
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Y
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 3322
- Employees
- 85
- Ownership type
- A
Citations
8 citations on file for this inspection.
5(a)(1)
- Issued
- Jul 1, 2002
- Abate by
- Aug 16, 2002
- Penalty
- Initial $1,300
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were potentially exposed to fire and explosion hazards from the ignition of natural gas leaks and/or the migration of compressed air into the natural gas supply system because the facilities natural gas torches lacked safety devices and/or had improper hose, hose connectors,and fittings: a.) Zurn Industries/Raspberry Street/Erie, PA /Molding Area & Melt Deck - Personnel operate torches that utilize a mixture of natural gas and compressed air to perform heating operations. These operations included but were not limited to preheating ladles, curing refractory material, and igniting coke. Flexible hoses were utilized to connect the building's natural gas piping system to the torch units. The flexible hoses and their associated coupling hardware (e.g. hose clamps with tightener screws and crimp clamps) were not listed and labeled for use with natural gas. In the melt deck area, Chicago fittings were utilized to connect the torch's flexible hose to a gas distribution tree. The Chicago fittings were not listed and labeled for use with natural gas. The torch unit assemblies and their associated flexible hose and building gas system connections were not equipped with safety devices (e.g. check valves, gas regulators, relief valves) to prevent the back flow of compressed air from the combustion barrel of the torch into the building's natural gas piping. ABATEMENT NOTE: Among other methods, feasible and acceptable abatement methods to correct the hazard are to comply with applicable requirements noted in NFPA 54/ANSI Z223.1-1999 ~ National Fuel Gas Code Section 5.1 and Section 5.5 Hose & Hose Connections: National Fuel Gas Code (NFPA 54/ANSI Z223.1) Sections 5.5.1 & 5.5.2 requires gas utilization equipment to be connected to the buildings piping with listed hosed and hose connectors. Back Flow Protection: National Fuel Gas Code NFPA 54/ANSI Z223.1 Section 5.1.5 requires that where air or oxygen under pressure is used in connection with the gas supply, effective means such as a back-pressure regulator and relief valve shall be provided to prevent air or oxygen from passing back into the gas piping.
Recent events (2)
- — I (O)
- — Z (S) $1300.00
1910.212 A01
- Issued
- Jul 1, 2002
- Abate by
- Aug 16, 2002
- Penalty
- Initial $975 · Current $634 Reduced
Recent events (2)
- — I (S) $634.00
- — Z (S) $975.00
1910.22 A02
- Issued
- Jul 1, 2002
- Abate by
- Aug 16, 2002
1910.23 A08
- Issued
- Jul 1, 2002
- Abate by
- Aug 16, 2002
1910.106 E02 II
- Issued
- Jul 1, 2002
- Abate by
- Aug 16, 2002
1910.132 A
- Issued
- Jul 1, 2002
- Abate by
- Jul 5, 2002
1910.1200 F05 I
- Issued
- Jul 1, 2002
- Abate by
- Jul 5, 2002
1910.1200 F05 II
- Issued
- Jul 1, 2002
- Abate by
- Jul 5, 2002
More inspections at Zurn Industries, INC. - Cast Metals Division
View Zurn Industries, INC. - Cast Metals Division's full OSHA safety record →
More inspections in this industry (NAICS 000000)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 303709018.