LINE LEXINGTON, PA —
OSHA Inspection: HETMAN TREE SERVICE
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of HETMAN TREE SERVICE in 766 WEST LINE LEXINGTON ROAD, LINE LEXINGTON, PA 18932 (NAICS 000000). OSHA activity number 303716369.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- HETMAN TREE SERVICE
- Site address
- 766 WEST LINE LEXINGTON ROAD
- City
- LINE LEXINGTON
- State
- PA
- ZIP
- 18932
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 7832
- Employees
- 13
- Ownership type
- A
Citations
8 citations on file for this inspection.
5(a)(1)
- Issued
- Jan 31, 2001
- Abate by
- Mar 5, 2001
- Penalty
- Initial $750 · Current $750
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to falling crane load(s): a) The Terex-RO 15-ton hydraulic truck crane (serial number 45907981915) had an improperly attached main load line (the dead end of the rope was clipped to the live end in a wedge socket) and the dead end of the rope showed damage evident of two-blocking. Among other methods, one feasible and acceptable abatement method to correct this hazard is to comply with the manufacturer's specifications and instructions, and to follow ANSI B30.5, both of which have specific requirements for wedge socket installation and anti-two-blocking. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement.
1910.212 A03 II
- Issued
- Jan 31, 2001
- Abate by
- Feb 8, 2001
- Penalty
- Initial $1,500 · Current $1,500
1910.180 D03
- Issued
- Jan 31, 2001
- Abate by
- Mar 5, 2001
- Penalty
- Initial $750 · Current $750
1910.180 D04
- Issued
- Jan 31, 2001
- Abate by
- Mar 5, 2001
1910.180 D06
- Issued
- Jan 31, 2001
- Abate by
- Mar 5, 2001
1910.180 G01
- Issued
- Jan 31, 2001
- Abate by
- Mar 5, 2001
1910.184 D
- Issued
- Jan 31, 2001
- Abate by
- Mar 5, 2001
- Penalty
- Initial $750 · Current $750
1904.2 A
- Issued
- Jan 31, 2001
- Abate by
- Mar 5, 2001
More inspections in this industry (NAICS 000000)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 303716369.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.