OMAHA, NE —
OSHA Inspection: HOUSE OF MUFFLERS & BRAKES
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of HOUSE OF MUFFLERS & BRAKES in 5815 CENTER, OMAHA, NE 68106 (NAICS 000000). OSHA activity number 303725253.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- HOUSE OF MUFFLERS & BRAKES
- Site address
- 5815 CENTER
- City
- OMAHA
- State
- NE
- ZIP
- 68106
- Mailing
- 8504 L STREET, OMAHA, NE 68127
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 7533
- Employees
- 5
- Ownership type
- A
Citations
5 citations on file for this inspection.
5(a)(1)
- Issued
- Dec 20, 2000
- Abate by
- Jan 22, 2001
- Penalty
- Initial $1,500 · Current $750 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: House of Mufflers and Brakes, 5815 Center St - The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to: Employees are exposed to potential crushing hazards while working around and under the automotive hoists located in the shop service area. Not all of the automotive lifts were equipped with functional safety devices nor maintained and inspected in accordance with the manufacturer's recommendations. The safety device on the lift in Bay 4 was not automatically functioning due to alterations of the safety device. The employer was not following maintenance and care procedures of the lift, as designated by the manufacturer, as evidenced by the inability of the manager to provide the manufacturer books to the CSHO and the lack of functional safety devices. The employer was not conducting scheduled inspections of the lifts to ensure that all components are in safe operating condition, as recommended by the Automotive Lift institute, Inc, ALOIM - 1994 Standard Approved as an American National Standard by American National Standards Institute. a)Qualified Inspection Documentation - Conduct lift inspections following the specific directions provided by the lift manufacturer in accordance with section 5.6.1 of ANSI/ALI ALOIM-1994. b)Inspection Points-Mechanical Lifts - Check chains and report excessive wear on links pins or side plates, deformed, bent, rusted or broken links, or presence of foreign material in accordance with section 5.6.4.2 of ANSI/ALI ALOIM-1994. c)Preventive Maintenance Procedure - Establish a periodic preventive maintenance procedure in accordance with the recommendations of the lift manufacturer in order to ensure the continued safe operation of the lift in accordance with section 6.1.1 of ANSI/ALI ALOIM-1994. d)Preventive Maintenance Documentation - Maintain a record of preventive maintenance procedures performed. Note specific checks made, parts replaced, adjustments made, results of any measurements and recommendations made in accordance with section 6.1.4 of ANSI/ALI ALOIM-1994. e)Preventive Maintenance Frequency - Follow the lift manufacturer recommendations for frequency of preventive maintenance in accordance with section 6.1.5 of ANSI/ALI ALOIM-1994. f)Repair Maintenance Documentation - Maintain a record of each repair maintenance procedure performed in accordance with section 6.1.5 of ANSI/ALI ALOIM 1994. g)Modifications - Do not make modifications or reconstruct any automotive lifts without the express written permission of the manufacturer performed in accordance with section 7. of ANSI/ALI ALOIM 1994. Abatement certification and abatement documentation is required for this violation. The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful. The abatement certification sheet is enclosed with the citations.ion
Recent events (2)
- — I (S) $750.00
- — Z (S) $1500.00
1910.147 C01
- Issued
- Dec 20, 2000
- Abate by
- Jan 22, 2001
- Penalty
- Initial $1,500 · Current $750 Reduced
Recent events (2)
- — I (S) $750.00
- — Z (S) $1500.00
1910.1200 E01
- Issued
- Dec 20, 2000
- Abate by
- Jan 22, 2001
1910.1200 F05 I
- Issued
- Dec 20, 2000
- Abate by
- Dec 28, 2000
1910.1200 F05 II
- Issued
- Dec 20, 2000
- Abate by
- Dec 28, 2000
More inspections in this industry (NAICS 000000)
More inspections in NE
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 303725253.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.