BRUNSWICK, GA —
OSHA Inspection: BROWNING TRUCKING
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of BROWNING TRUCKING in 1400 WEST 9TH STREET, BRUNSWICK, GA 31520 (NAICS 000000). OSHA activity number 303770788.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BROWNING TRUCKING
- Site address
- 1400 WEST 9TH STREET
- City
- BRUNSWICK
- State
- GA
- ZIP
- 31520
- Mailing
- 1093 HWY 19 SOUTH, GLENWOOD, GA 30428
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- Y
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 2621
- Employees
- 820
- Ownership type
- A
Citations
4 citations on file for this inspection.
5(a)(1)
- Issued
- Jul 16, 2002
- Abate by
- Jul 19, 2002
- Penalty
- Initial $2,125 · Current $2,125
General-duty citation text
P.L. 91-596 Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that an employee was exposed to steam and condensate that caused serious burns following the catastrophic failure of a pressure vessel. a) On the 2nd floor of the #4 powerhouse - The feedwater stage heater, a shell and tube heat exchanger containing tubes of water under 1800 psi pressure at a temperature of 270 degrees fahrenheit had not been inspected by an NBIC (National Board of Boiler and Pressure Vessel Inspectors) commissioned inspector. Deteriorated tubes allowed leakage of the high pressure water into the shell (rated for 200 psi) which did not have a pressure relieving device. Overpressurization caused the vessel to rupture, spewing steam and condensate on an employee, on or about 01/22/02. Among other methods, feasible and acceptable means of abatement are a) to have a commissioned inspector evaluate the condition of the vessel. NBIC, Part RB-3237 requires the maximum period between internal inspections or a complete on-stream evaluation of the vessel of not more than one-half of the estimated remaining life of the vessel or ten years, whichever is less; and b) to install a safety relief device on the pressure vessel. ASME Boiler & Pressure Vessel Code, Section VIII, Division I, paragraph UG-125 (a) requires that all pressure vessels be provided with protective devices in accordance with the requirements of UG-125 through UG- 136.
1910.147 C05 II
- Issued
- Jul 16, 2002
- Abate by
- Jul 26, 2002
- Penalty
- Initial $2,125 · Current $600 Reduced
Recent events (2)
- — I (O) $600.00
- — Z (S) $2125.00
1910.147 C06 IA
- Issued
- Jul 16, 2002
- Abate by
- Aug 30, 2002
- Penalty
- Initial $1,275 · Current $1,275
1910.147 C06 IC
- Issued
- Jul 16, 2002
- Abate by
- Aug 30, 2002
Recent events (2)
- — I (O)
- — Z (S)
More inspections at Browning Trucking
View Browning Trucking's full OSHA safety record →
More inspections in this industry (NAICS 000000)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 303770788.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.