Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: COLLINSVILLE CUSTOM KITCHENS, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of COLLINSVILLE CUSTOM KITCHENS, INC. in #6 SHIBER COURT, MARYVILLE, IL 62062 (NAICS 333512). OSHA activity number 303818397.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Collinsville Custom Kitchens, INC. — free Get an email when a new federal OSHA severe-injury report for Collinsville Custom Kitchens, INC. is published. One employer, no account, unsubscribe in one click.
Site address
#6 SHIBER COURT
City
MARYVILLE
State
IL
ZIP
62062
Mailing
P.O. BOX 461, COLLINSVILLE, IL 62234
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Y
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333512
SIC code (legacy)
2511
Employees
12
Ownership type
A
Industry flags
Manufacturing safety.

6 citations on file for this inspection.

5(a)(1)

Serious Gravity 02 1 instance 1 exposed
Issued
Jul 15, 2003
Abate by
Aug 29, 2003
Penalty
Initial $600 · Current $360 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards
that were causing or likely to cause physical harm to employees in that
employees were
exposed to flying plastic projectiles due to an excessive operating
pressure in excess of 100
psi as referenced in ANSI/ASME B31.8-1999.  Among other methods, one
feasible and
accepted means to correct this hazard is to replace the current PVC
compressed air piping
system with materials suitable for maximum air pressure such as metal
pipes or approved
hose reels:
In the Veneer Department, an 1 1/2" PVC air system spanning approximately
110'
was used in the transport of compressed air at an operating pressure of
approximately
150 psi supplied by an Ingersoll Rand Air Compressor, Model 7100, Serial
01002243, 80 gal. capacity.  The above stated hazard presented a potential
for PVC
explosion with likely lacerations to exposed employees from plastic
shrapnel.
**Abatement documentation required for this item**
Recent events (2)
  • — I (S) $360.00
  • — Z (S) $600.00

1910.106 E06 II

Serious Gravity 02 1 instance 1 exposed
Issued
Jul 15, 2003
Abate by
Jul 25, 2003
Penalty
Initial $600 · Current $360 Reduced
Recent events (2)
  • — I (S) $360.00
  • — Z (S) $600.00

1910.213 H04

Serious Gravity 10 1 instance 1 exposed
Issued
Jul 15, 2003
Abate by
Jul 21, 2003
Penalty
Initial $1,500 · Current $900 Reduced
Recent events (2)
  • — I (S) $900.00
  • — Z (S) $1500.00

1910.305 B01

Serious Gravity 02 1 instance 1 exposed
Issued
Jul 15, 2003
Abate by
Jul 25, 2003
Penalty
Initial $600 · Current $360 Reduced
Recent events (2)
  • — I (S) $360.00
  • — Z (S) $600.00

1910.305 G01 III

Serious Gravity 01 1 instance 1 exposed
Issued
Jul 15, 2003
Abate by
Aug 8, 2003
Penalty
Initial $450 · Current $270 Reduced
Recent events (2)
  • — I (S) $270.00
  • — Z (S) $450.00

1910.1200 H

Other-than-serious Gravity 01 1 instance 2 exposed
Issued
Jul 15, 2003
Abate by
Aug 29, 2003