WOOD RIVER, IL —
OSHA Inspection: MISS.RIV.FEST.DBA MISSISSIPPI RIVER CONSTRUCTION
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of MISS.RIV.FEST.DBA MISSISSIPPI RIVER CONSTRUCTION in ROUTE 111, WOOD RIVER, IL 62095 (NAICS 236220). OSHA activity number 303819049.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MISS.RIV.FEST.DBA MISSISSIPPI RIVER CONSTRUCTION
- Site address
- ROUTE 111
- City
- WOOD RIVER
- State
- IL
- ZIP
- 62095
- Mailing
- 201 SCOTT-TROY ROAD, O'FALLON, IL 62269
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236220
- SIC code (legacy)
- 1542
- Employees
- 6
- Ownership type
- A
Citations
5 citations on file for this inspection.
5(a)(1)
- Issued
- Mar 24, 2004
- Abate by
- Apr 12, 2004
- Penalty
- Initial $1,500 · Current $1,500
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to: a)Employees of Mississippi River Construction were exposed to hazards such as, but not limited to falls and being crushed from collapsing trusses during the roofing and sheathing installation at the site of a new retail store on Illinois Hwy. 111 in Wood River, Illinois on or before September 29, 2003. The methods of contruction and bracing of roof trusses were not followed to prevent them from collapsing during periods of high winds prior to completion of the sheathing. Lateral bottom chord bracing lapped over two trusses, diagonal braces every ten truss spaces on the bottom chord, and bracing on the top chord of the trusses was not used to stabilize the trusses while sheathing was being installed. One method of abatement among others would be to follow the recommendations of the Truss Plate Institute HIB-91 Summary Sheet or the information on truss erection provided by the manufacturer at the time of delivery. **ABATEMENT CERTIFICATION AND DOCUMENTATION REQUIRED FOR THIS ITEM.**D
1926.501 B10
- Issued
- Mar 24, 2004
- Abate by
- Apr 12, 2004
- Penalty
- Initial $1,500 · Current $1,500
1926.503 A01
- Issued
- Mar 24, 2004
- Abate by
- Apr 12, 2004
1926.1053 B01
- Issued
- Mar 24, 2004
- Abate by
- Apr 12, 2004
- Penalty
- Initial $1,050 · Current $1,050
1926.1060 A
- Issued
- Mar 24, 2004
- Abate by
- Apr 12, 2004
More inspections at Miss.Riv.Fest.Dba Mississippi River Construction
View Miss.Riv.Fest.Dba Mississippi River Construction's full OSHA safety record →
More inspections in this industry (NAICS 236220)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 303819049.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.