Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CENTRAL STORAGE AND WAREHOUSE COMPANY

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of CENTRAL STORAGE AND WAREHOUSE COMPANY in 4309 COTTAGE GROVE ROAD, MADISON, WI 53707 (NAICS 000000). OSHA activity number 303862031.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Central Storage and Warehouse Company — free Get an email when a new federal OSHA severe-injury report for Central Storage and Warehouse Company is published. One employer, no account, unsubscribe in one click.
Site address
4309 COTTAGE GROVE ROAD
City
MADISON
State
WI
ZIP
53707
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Y
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
000000
SIC code (legacy)
4225
Employees
19
Ownership type
A

2 citations on file for this inspection.

5(a)(1)

Serious Gravity 03 1 instance 17 exposed
Issued
Apr 18, 2001
Abate by
May 1, 2001
Penalty
Initial $1,250 · Current $875 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees in that employees
were exposed to: possible fall to hoistway (elevator shaft) bottom from
first floor landing.
On or about April 6, 2001, on first floor, the freight elevator gate was
found to have the
electrical interlock taped closed so that the elevator could be operated
with the gate up.
"AMONG OTHER METHODS, ONE FEASIBLE AND ACCEPTABLE ABATEMENT
METHOD  TO CORRECT THIS HAZARD IS:
To maintain the electrical/mechanical interlocks in good repair. Meeting
the requirements of
ANSI A17.1-1971
Section 111 - Hoistway-door locking devices, car door or gate electric
contacts, hoistway access
switches, and elevator parking devices;
Section 1002 - Maintenance, Rule 1002.4   Making Safety Devices
Inoperative.  No person shall
at any time make any required safety device or electrical protective
device inoperative, except
where necessary during tests, inspections, and maintenance.  Immediately
upon completion of
such tests, inspections, and maintenance, such devices shall be restored
to their normal operating
condition  in conformity with the applicable requirements (see Rule 210.7)
Recent events (2)
  • — I (S) $875.00
  • — Z (S) $1250.00

1910.303 G01 II

Other-than-serious Gravity 01 1 instance 2 exposed
Issued
Apr 18, 2001
Abate by
Apr 23, 2001
Recent events (2)
  • — I (O)
  • — Z (O)

View Central Storage and Warehouse Company's full OSHA safety record →