OSHA Inspection: RANGEN INC.

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of RANGEN INC. in 115 13TH AVE N, BUHL, ID 83316 (NAICS 000000). OSHA activity number 303948921.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Rangen INC. — free Get an email when a new federal OSHA severe-injury report for Rangen INC. is published. One employer, no account, unsubscribe in one click.
Establishment
RANGEN INC.
Site address
115 13TH AVE N
City
BUHL
State
ID
ZIP
83316
Mailing
P.O. BOX 706, BUHL, ID 83316
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Data loaded
NAICS code
000000
SIC code (legacy)
2048
Employees
140
Ownership type
A

5 citations on file for this inspection.

5(a)(1)

Serious Gravity 03 3 instances 10 exposed
Issued
May 25, 2001
Abate by
Jul 13, 2001
Penalty
Initial $1,375 · Current $700 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer
did not
furnish employment and a place of employment which was free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees in that
employees were exposed to potential fall hazards and/or crushing injuries
from incorrectly
guarded landings and elevator cars:
(a)General Feeds Division, Building #1, Receiving: The hand operated
elevator
was not installed in accordance with American National Standard Safety Code
For Elevators (ANSI A17.1-1960).  Deficiencies include, but may not be
limited to the rule noted below:
(1) The elevator car was not enclosed on the sides not used for entrance,
exposing employees riding the car to fall hazards. (Rule 601.1)
(b)Commodities Division, Building #18: The powered electric passenger
elevator
was not installed in accordance with American National Standard Safety Code
For Elevators Dumbwaiters and Escalators (ANSI A17.1-1960) and the Safety
Code For Existing Elevators and Escalators (ANSI A17.3-1986).  Deficiencies
include, but may not be limited to the rules noted below:
(1) The hoistway-doors did not have hoistway-door interlocks to prevent a
hoistway-door from being opened when the elevator is not at that landing
zone.  In the case that a door was opened while the car was not at the
landing,
employees on the upper landing would be exposed to an approximate 66 feet
high fall hazard, and employees on the lower level would be exposed to
crushing hazards. (ANSI A17.1, Rule 111.1a)
(2) The elevator car door was not so arranged to prevent opening more than
4
inches from inside the car when the car is outside the unlocking zone.
(ANSI
A17.3, Rule 2.7.4)
(c)Aqua Feeds Division, Building #5:  The powered electric passenger
elevator
was not installed in accordance with American National Standard Safety Code
For Elevators Dumbwaiters and Escalators (ANSI A17.1-1960) and the Safety
Code For Existing Elevators and Escalators (ANSI A17.3-1986).  Deficiencies
include, but may not be limited to the rules noted below:
(1) The hoistway-doors did not have hoistway-door interlocks to prevent a
hoistway-door from being opened when the elevator is not at that landing
zone.  In the case that a door was opened while the car was not at the
landing,
employees on the upper landing would be exposed to an approximate 40 feet
high fall hazard, and employees on the lower level would be exposed to
crushing hazards. (ANSI A17.1, Rule 111.1a)
(2) The elevator car door was not so arranged to prevent opening more than
4
inches from inside the car when the car is outside the unlocking zone.
(ANSI
A17.3, Rule 2.7.4)
Among other methods, feasible and acceptable abatement methods to correct
these hazards
include:
- Compliance with applicable ANSI standards, including replacing the
hand-operated
car with one that is enclosed;
- Construction of an appropriate enclosure for the hand-operated elevator
car;
- Installation of appropriate interlocks on the electric elevators to
prevent hoistway-
doors and car-doors from opening unless the car is at the landing.
Note: Abatement certification and supporting documentation are required
for this item.
Recent events (2)
  • — I (S) $700.00
  • — Z (S) $1375.00

1910.95 G06

Other-than-serious Gravity 01 1 instance 1 exposed
Issued
May 25, 2001
Abate by
Jul 13, 2001
Recent events (2)
  • — I (O)
  • — Z (O)

1910.134 D01 III

Other-than-serious Gravity 01 1 instance 10 exposed
Issued
May 25, 2001
Abate by
Sep 13, 2001
Recent events (2)
  • — I (O)
  • — Z (O)

1910.1200 G01

Other-than-serious Gravity 01 1 instance 10 exposed
Issued
May 25, 2001
Abate by
Jun 21, 2001
Recent events (2)
  • — I (O)
  • — Z (O)

1910.1200 H03 II

Other-than-serious Gravity 01 1 instance 10 exposed
Issued
May 25, 2001
Abate by
Jun 21, 2001
Recent events (2)
  • — I (O)
  • — Z (O)

View Rangen INC.'s full OSHA safety record →