MELROSE PARK, IL —
OSHA Inspection: MARVEL ENGINEERING CO.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of MARVEL ENGINEERING CO. in 2085 HAWTHORNE, MELROSE PARK, IL 60160 (NAICS 000000). OSHA activity number 303995666.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MARVEL ENGINEERING CO.
- Site address
- 2085 HAWTHORNE
- City
- MELROSE PARK
- State
- IL
- ZIP
- 60160
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 3599
- Employees
- 22
- Ownership type
- A
Citations
1 citation on file for this inspection.
5(a)(1)
- Issued
- Nov 7, 2000
- Abate by
- Nov 13, 2000
- Penalty
- Initial $1,500 · Current $1,000 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to: Employee(s) performing pneumatic leak tests of die cast assembly covers were exposed to the hazard of being struck by flying fragments from the covers if they were to explode or burst during the pressurization of the test fixture with nitrogen. Among others, one method of abatement to eliminate this hazard would be to: (1), use a type of regulator that, by design, would limit the nitrogen gas flow into the test fixture to the maximum needed for the test, i.e., 150 p.s.i.; (2), enclose the test fixture with a device that would contain the flying fragments and isolate them from the operator or other employees; (3), install a safety relief valve on the test fixture. (4), follow the requirements found in ASME Boiler and Pressure Vessel Code, Section VIII, Unfired Pressure Vessels, as referenced in OSHA Standard 29 CFR 1910.6. Abatement documentation is required for this item in accordance with the requirement of 29 CFR 1903.19(d).
Recent events (2)
- — I (S) $1000.00
- — Z (S) $1500.00
More inspections at Marvel Engineering CO.