Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MARVEL ENGINEERING CO.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of MARVEL ENGINEERING CO. in 2085 HAWTHORNE, MELROSE PARK, IL 60160 (NAICS 000000). OSHA activity number 303995666.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Marvel Engineering CO. — free Get an email when a new federal OSHA severe-injury report for Marvel Engineering CO. is published. One employer, no account, unsubscribe in one click.
Site address
2085 HAWTHORNE
City
MELROSE PARK
State
IL
ZIP
60160
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Data loaded
NAICS code
000000
SIC code (legacy)
3599
Employees
22
Ownership type
A

1 citation on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 2 exposed
Issued
Nov 7, 2000
Abate by
Nov 13, 2000
Penalty
Initial $1,500 · Current $1,000 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees in that employees
were exposed to:
Employee(s) performing pneumatic leak tests of die cast assembly covers
were exposed to the
hazard of being struck by flying fragments from the covers if they were to
explode or burst
during the pressurization of the test fixture with nitrogen.
Among others, one method of abatement to eliminate this hazard would be to:
(1), use a type of regulator that, by design, would limit the nitrogen gas
flow into
the test fixture to the maximum needed for the test, i.e., 150 p.s.i.;
(2), enclose the test fixture with a device that would contain the flying
fragments
and isolate them from the operator or other employees;
(3), install a safety relief valve on the test fixture.
(4), follow the requirements found in ASME Boiler and Pressure Vessel Code,
Section VIII, Unfired Pressure Vessels, as referenced in OSHA Standard 29
CFR
1910.6.
Abatement documentation is required for this item in accordance with the
requirement of
29 CFR 1903.19(d).