GASTONIA, NC —
OSHA Inspection: FRANK COLLIER DBA COLLIER GUTTERING
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of FRANK COLLIER DBA COLLIER GUTTERING in 3129 SPRINGVALLEY DR, GASTONIA, NC 28052 (NAICS 000000). OSHA activity number 304074115.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FRANK COLLIER DBA COLLIER GUTTERING
- Site address
- 3129 SPRINGVALLEY DR
- City
- GASTONIA
- State
- NC
- ZIP
- 28052
- Mailing
- 408 E. WALNUT AVE, GASTONIA, NC 28054
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 8999
- Employees
- 2
- Ownership type
- A
- Industry flags
- Construction safety.
Citations
2 citations on file for this inspection.
95012901
- Issued
- Nov 21, 2000
- Abate by
- Nov 27, 2000
- Penalty
- Initial $350 · Current $350
General-duty citation text
North Carolina General Statute 95-129(1) of the Occupational Safety and Health Act of North Carolina: The employer did not furnish to each of his employees conditions of employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees: a)jobsite; four seasons apartments, springview drive - employees removing gutters came into contact with overhead power lines. NOTE: One feasible and acceptable means of abatement is to have the power lines deenergized before removing the gutters. OR IN THE ALTERNATIVE: CFR 1910.333(c)(3)(i)Unqualified persons(a)when an unqualified person is working in an elevated position near overhead power lines, the location shall be such that the person and the longest conductive object he or she may contact cannot come closer to any unguarded, energized overhead line than the following distancs: (1) for voltages to ground 50 kv or below - 10 feet (305cm)
1926.501 B13
- Issued
- Nov 21, 2000
- Abate by
- Nov 27, 2000