Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: FRANK COLLIER DBA COLLIER GUTTERING

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of FRANK COLLIER DBA COLLIER GUTTERING in 3129 SPRINGVALLEY DR, GASTONIA, NC 28052 (NAICS 000000). OSHA activity number 304074115.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Frank Collier DBA Collier Guttering — free Get an email when a new federal OSHA severe-injury report for Frank Collier DBA Collier Guttering is published. One employer, no account, unsubscribe in one click.
Site address
3129 SPRINGVALLEY DR
City
GASTONIA
State
NC
ZIP
28052
Mailing
408 E. WALNUT AVE, GASTONIA, NC 28054
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Data loaded
NAICS code
000000
SIC code (legacy)
8999
Employees
2
Ownership type
A
Industry flags
Construction safety.

2 citations on file for this inspection.

95012901

Serious 1 instance 1 exposed
Issued
Nov 21, 2000
Abate by
Nov 27, 2000
Penalty
Initial $350 · Current $350
North Carolina General Statute 95-129(1) of the Occupational Safety
and Health Act of North Carolina:  The employer did not furnish to
each of his employees conditions of employment and a place of
employment which were free from recognized hazards that were
causing or likely to cause death or serious physical harm to
employees:
a)jobsite; four seasons apartments, springview drive -
employees removing gutters came into contact with
overhead power lines.
NOTE:  One feasible and acceptable means of abatement is to
have the power lines deenergized before removing the gutters.
OR IN THE ALTERNATIVE:
CFR 1910.333(c)(3)(i)Unqualified persons(a)when an unqualified
person is working in an elevated position near overhead power
lines, the location shall be such that the person and the
longest conductive object he or she may contact cannot come
closer to any unguarded, energized overhead line than the
following distancs:  (1) for voltages to ground 50 kv or below
- 10 feet (305cm)

1926.501 B13

Serious 1 instance 1 exposed
Issued
Nov 21, 2000
Abate by
Nov 27, 2000

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 304074115.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.