Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,871Inspections Most recent open 2026-07-30 Last loaded 2026-08-03

OSHA Inspection: TROY FASHION INC.

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of TROY FASHION INC. in 809-811 WEST STREET, UNION CITY, NJ 07087 (NAICS 000000). OSHA activity number 304076359.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Troy Fashion INC. for free Get an email when a new federal OSHA severe-injury report for Troy Fashion INC. is published. One employer, no account, unsubscribe in one click.
Establishment
TROY FASHION INC.
Site address
809-811 WEST STREET
City
UNION CITY
State
NJ
ZIP
07087
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Data loaded
NAICS code
000000
SIC code (legacy)
5137
Employees
70
Ownership type
A

4 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 2 exposed
Issued
Jan 9, 2001
Abate by
Feb 5, 2001
Penalty
Initial $3,500 · Current $1,750 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees in that employees
were exposed to crushing or decapitation hazard.
a) Material Handling Hoist/Dumbwaiter:
All elevator hoistway-landing openings were not provided with a guard the
full height and width
of the opening.
Violation observed on or about 01/05/01.
Among other feasible and acceptable methods(s) of abatement:
1) To install a hoistway guard on each floor. Types may include horizontal
slide, single or
multisection; swing, single section; combination horizontal slide and
swing; or center-opening.
Each guard shall have electrical contacts, interlocked with the hoistway
system,
at each level;
preventing any door from opening, unless the hoist is stationary at a
level.
Reference ANSI/ASME A17.1 - 1981, "Safety Code for Elevators and
Escalators", Part I
"Hoistways, Hoist Enclosures and Related Construction for Electric
Elevators", Section 110,
"Protection of Hoistway-Landing Openings", Rule 110.1 "Entrance and
Emergency Doors
Required".
Recent events (2)
  • · I (S) $1750.00
  • · Z (S) $3500.00

1910.219 D01

Serious Gravity 01 2 instances 1 exposed
Issued
Jan 9, 2001
Abate by
Feb 5, 2001
Penalty
Initial $750 · Current $375 Reduced
Recent events (2)
  • · I (S) $375.00
  • · Z (S) $750.00

1910.219 E03 I

Serious Gravity 01 2 instances 1 exposed
Issued
Jan 9, 2001
Abate by
Feb 5, 2001

1910.141 D01

Other-than-serious Gravity 01 1 instance 2 exposed
Issued
Jan 9, 2001
Abate by
Feb 5, 2001

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 304076359.