LUBBOCK, TX —
OSHA Inspection: KEY ENERGY SERVICES, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of KEY ENERGY SERVICES, INC. in 4100 E ERSKIN & IDALOU RD. 600, LUBBOCK, TX 79401 (NAICS 000000). OSHA activity number 304118763.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- KEY ENERGY SERVICES, INC.
- Site address
- 4100 E ERSKIN & IDALOU RD. 600
- City
- LUBBOCK
- State
- TX
- ZIP
- 79401
- Mailing
- P.O. BOX 1326, LEVELLAND, TX 79336
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 1389
- Employees
- 45
- Ownership type
- A
Citations
1 citation on file for this inspection.
1910.181 E02
- Issued
- Jul 2, 2002
- Abate by
- Jul 8, 2002
- Penalty
- Initial $7,000 · Current $1,000 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the condition(s) listed below: For the period of time up to and including 06/20/02, at the job-site of Key Energy Services, Inc., located 1/2 mile East of the intersection of East Erskine and the Idalou Rd, Lubbock, TX 79401: Employees were exposed to the hazards of being struck-by a collapsing work-over rig. The conditions were created when the work-over rig guy-lines were connected to unserviceable and untested anchors (two of the anchors were bent and none of the anchors were tagged to indicate they had been tested within the recommended 2 year interval, as per American Petroleum Institute Recommended Practice 4G (RP 4G). Among others, some feasible and acceptable methods to correct these hazards would be to: 1) Ensure that the physical condition of the guy-line anchors is verified by performing a before use inspection. 2) Verify, during the before use inspection, that the anchors have been tagged to indicated that they have been inspected / pull tested within two years. 3) Train work-over / pulling unit operators and supervisors that it is their responsibility to ensure that under no circumstance will these units rig up to any anchor that is unserviceable, has not been inspected, pull tested or tagged accordingly.
Recent events (2)
- — I (O) $1000.00
- — Z (S) $7000.00
More inspections at KEY Energy Services, INC.
View KEY Energy Services, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 000000)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 304118763.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.