Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: TOTAL JETTING, INC.

Accident-driven inspection · Safety discipline

On , OSHA opened an accident-driven safety inspection of TOTAL JETTING, INC. in 2501 GRANDVIEW, ODESSA, TX 79766 (NAICS 562910). OSHA activity number 304120298.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Total Jetting, INC. — free Get an email when a new federal OSHA severe-injury report for Total Jetting, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
TOTAL JETTING, INC.
Site address
2501 GRANDVIEW
City
ODESSA
State
TX
ZIP
79766
Mailing
3911 WEST ARCADIA, ODESSA, TX 79764
Inspection type
Accident-driven (A)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
562910
SIC code (legacy)
1799
Employees
28
Ownership type
A

1 citation on file for this inspection.

5(a)(1)

Willful Gravity 03 2 instances 6 exposed
Issued
Apr 16, 2003
Abate by
Apr 22, 2003
Penalty
Initial $22,000 · Current $22,000
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees in that employees
were exposed to the condition(s) listed below:
a)  The work site located at 2495 Grandview in Odessa,Texas; on or about
October 17, 2002,
employees were exposed to a water-injection/struck-by hazard associated
with the use of a high
pressure  8,000 psi control gun being used to water blast the interior of
a vessel at the site.
Subsequent analysis revealed that the control gun being used for the water
blasting operation had
been modified from the original manufactured length of 48 inches, to a
length of 34 inches, and
the  shoulder support and barrel handle were absent.
Among other methods, one reasonable means of abatement would be to assure
that control gun
assemblies are maintained according to the manufacturer's guidelines,and
that
employees are
thoroughly trained in the proper use and hazards of high pressure
equipment.
Recent events (3)
  • — A (W) $22000.00
  • — I (W) $11000.00
  • — Z (W) $22000.00

View Total Jetting, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 304120298.