ODESSA, TX —
OSHA Inspection: TOTAL JETTING, INC.
Accident-driven inspection · Safety discipline
At a glance
On , OSHA opened an accident-driven safety inspection of TOTAL JETTING, INC. in 2501 GRANDVIEW, ODESSA, TX 79766 (NAICS 562910). OSHA activity number 304120298.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TOTAL JETTING, INC.
- Site address
- 2501 GRANDVIEW
- City
- ODESSA
- State
- TX
- ZIP
- 79766
- Mailing
- 3911 WEST ARCADIA, ODESSA, TX 79764
What kind of inspection was it?
- Inspection type
- Accident-driven (A)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 562910
- SIC code (legacy)
- 1799
- Employees
- 28
- Ownership type
- A
Citations
1 citation on file for this inspection.
5(a)(1)
- Issued
- Apr 16, 2003
- Abate by
- Apr 22, 2003
- Penalty
- Initial $22,000 · Current $22,000
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the condition(s) listed below: a) The work site located at 2495 Grandview in Odessa,Texas; on or about October 17, 2002, employees were exposed to a water-injection/struck-by hazard associated with the use of a high pressure 8,000 psi control gun being used to water blast the interior of a vessel at the site. Subsequent analysis revealed that the control gun being used for the water blasting operation had been modified from the original manufactured length of 48 inches, to a length of 34 inches, and the shoulder support and barrel handle were absent. Among other methods, one reasonable means of abatement would be to assure that control gun assemblies are maintained according to the manufacturer's guidelines,and that employees are thoroughly trained in the proper use and hazards of high pressure equipment.
Recent events (3)
- — A (W) $22000.00
- — I (W) $11000.00
- — Z (W) $22000.00
More inspections at Total Jetting, INC.
View Total Jetting, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 562910)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 304120298.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.