Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,193,745Inspections Most recent open 2026-08-06 Last loaded 2026-08-10

OSHA Inspection: TIRE DISTRIBUTORS INC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of TIRE DISTRIBUTORS INC in 1908 SOUTH LOUDOUN STREET, WINCHESTER, VA 22601 (NAICS 000000). OSHA activity number 304130701.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Tire Distributors INC for free Get an email when a new federal OSHA severe-injury report for Tire Distributors INC is published. One employer, no account, unsubscribe in one click.
Site address
1908 SOUTH LOUDOUN STREET
City
WINCHESTER
State
VA
ZIP
22601
Mailing
1908 S. LOUDOUN ST., WINCHESTER, VA 22601
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Data loaded
NAICS code
000000
SIC code (legacy)
5014
Employees
34
Ownership type
A
Industry flags
Manufacturing safety.

3 citations on file for this inspection.

510001 A

Serious 1 instance 2 exposed
Issued
Apr 23, 2001
Abate by
Oct 28, 2001
Penalty
Initial $625 · Current $407 Reduced
Code of Virginia - 40.1-51.1(a): The employer, Tire Distribution Inc., did
not furnish each of
their employees a safe employment and a place of employment which is free
from recognized
hazards that are causing or likely to cause death or serious physical harm
to employees, in that
employees operate a freight elevator which exposes them to:
(a) Amputations, fractures, or a permanent disability by not having a door
interlocking device or
gate with mechanical locks & electric contacts to prevent the elevators
travel when the door is
open.
(b) Amputations, fractures, or a permanent disability by not having their
elevator(s) regularly
inspected.  ANSI standard 17.1-1990 requires elevators to be inspected at
intervals not longer
than six months, including Routine, Periodic Inspections (annually & test)
and five year test
requirements.
This hazard is recognized throughout the industry; and by ANSI  A17.1990,
American National
Standards Safety Code for Elevators and Escalators.
One feasible and acceptable abatement method, among others, to correct
this hazard is to equip
the elevator with  Hoist-door locking devices and to inspect and test
elevators to determine their
safety and compliance with the requirements of this code before being
placed in service.
The freight elevator door is rusted/corroded open, and would not close
when the elevator is
departs the landing zone on the 1st floor level, or  second floor.  It is
not equipped with an
interlock device which prevents the elevator from traveling between the
1st floor and 2nd floor
when the overhead door open.
The freight elevators are not inspected at intervals at least every six
months: Routine and
Periodic inspections were not performed in the past year.
Recent events (3)
  • · Y (S) $407.00
  • · P (S) $625.00
  • · Z (S) $625.00

1910.23 C01

Deleted Serious 2 instances 2 exposed
Issued
Apr 23, 2001
Abate by
May 1, 2001
Penalty
Initial $625 · Current $625
Recent events (2)
  • · Y (S) $625.00
  • · Z (S) $625.00

ARM0060 A

Other-than-serious 1 instance 10 exposed
Issued
Apr 23, 2001
Abate by
Jun 8, 2001
Recent events (2)
  • · Y (O)
  • · Z (O)

View Tire Distributors INC's full OSHA safety record →