WINCHESTER, VA ·
OSHA Inspection: TIRE DISTRIBUTORS INC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of TIRE DISTRIBUTORS INC in 1908 SOUTH LOUDOUN STREET, WINCHESTER, VA 22601 (NAICS 000000). OSHA activity number 304130701.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TIRE DISTRIBUTORS INC
- Site address
- 1908 SOUTH LOUDOUN STREET
- City
- WINCHESTER
- State
- VA
- ZIP
- 22601
- Mailing
- 1908 S. LOUDOUN ST., WINCHESTER, VA 22601
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 5014
- Employees
- 34
- Ownership type
- A
- Industry flags
- Manufacturing safety.
Citations
3 citations on file for this inspection.
510001 A
- Issued
- Apr 23, 2001
- Abate by
- Oct 28, 2001
- Penalty
- Initial $625 · Current $407 Reduced
General-duty citation text
Code of Virginia - 40.1-51.1(a): The employer, Tire Distribution Inc., did not furnish each of their employees a safe employment and a place of employment which is free from recognized hazards that are causing or likely to cause death or serious physical harm to employees, in that employees operate a freight elevator which exposes them to: (a) Amputations, fractures, or a permanent disability by not having a door interlocking device or gate with mechanical locks & electric contacts to prevent the elevators travel when the door is open. (b) Amputations, fractures, or a permanent disability by not having their elevator(s) regularly inspected. ANSI standard 17.1-1990 requires elevators to be inspected at intervals not longer than six months, including Routine, Periodic Inspections (annually & test) and five year test requirements. This hazard is recognized throughout the industry; and by ANSI A17.1990, American National Standards Safety Code for Elevators and Escalators. One feasible and acceptable abatement method, among others, to correct this hazard is to equip the elevator with Hoist-door locking devices and to inspect and test elevators to determine their safety and compliance with the requirements of this code before being placed in service. The freight elevator door is rusted/corroded open, and would not close when the elevator is departs the landing zone on the 1st floor level, or second floor. It is not equipped with an interlock device which prevents the elevator from traveling between the 1st floor and 2nd floor when the overhead door open. The freight elevators are not inspected at intervals at least every six months: Routine and Periodic inspections were not performed in the past year.
Recent events (3)
- · Y (S) $407.00
- · P (S) $625.00
- · Z (S) $625.00
1910.23 C01
- Issued
- Apr 23, 2001
- Abate by
- May 1, 2001
- Penalty
- Initial $625 · Current $625
Recent events (2)
- · Y (S) $625.00
- · Z (S) $625.00
ARM0060 A
- Issued
- Apr 23, 2001
- Abate by
- Jun 8, 2001
Recent events (2)
- · Y (O)
- · Z (O)
More inspections at Tire Distributors INC
View Tire Distributors INC's full OSHA safety record →
More inspections in this industry (NAICS 000000)
More inspections in VA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 304130701.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.