GENEVA, IL —
OSHA Inspection: INDUSTRIAL HARD CHROME LTD.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of INDUSTRIAL HARD CHROME LTD. in 501 FLUID POWER DR., GENEVA, IL 60134 (NAICS 000000). OSHA activity number 304154347.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- INDUSTRIAL HARD CHROME LTD.
- Site address
- 501 FLUID POWER DR.
- City
- GENEVA
- State
- IL
- ZIP
- 60134
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 3471
- Employees
- 98
- Ownership type
- A
- Industry flags
- Manufacturing safety.
Citations
6 citations on file for this inspection.
1910.23 C01
- Issued
- Mar 12, 2001
- Abate by
- Mar 15, 2001
- Penalty
- Initial $446 · Current $313 Reduced
Recent events (2)
- — I (S) $312.50
- — Z (S) $446.00
5(a)(1)
- Issued
- Mar 12, 2001
- Abate by
- Mar 15, 2001
- Penalty
- Initial $446 · Current $313 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards in that employees were subject to being struck by falling loads due to inadequate lifting devices: A.At Industrial Hard Chrome a custom-made sling device used to lift barrels, in the dock area, had no weight capacity or any proof testing performed on it. B.The spreader bar used to lift rods in the polishing area had no capacity markings. Among others, a feasible and acceptable abatement method is to comply with the American national Standards Institute (ANSI) standard B30.20 Below-the-Hook Lifting Devices and: 1.Provide the rated load on any custom made lifting device. 2.Design the lifting device to withstand the forces imposed by its rated load with a minimum design factor of 3. 3.Provide initial, frequent, and periodic inspections of the lifting devices. 4.Ensure that the initial proof testing of 125of the rated load was conducted. NO CERTIFICATION OR DOCUMENTATION REQUIRED FOR THIS ITEM.
Recent events (2)
- — I (S) $312.50
- — Z (S) $446.00
1910.335 A02 II
- Issued
- Mar 12, 2001
- Abate by
- Mar 15, 2001
- Penalty
- Initial $446 · Current $312 Reduced
Recent events (2)
- — I (S) $312.00
- — Z (S) $446.00
1910.178 A06
- Issued
- Mar 12, 2001
- Abate by
- Mar 15, 2001
Recent events (2)
- — I (O)
- — Z (O)
1910.178 P01
- Issued
- Mar 12, 2001
- Abate by
- Mar 15, 2001
Recent events (2)
- — I (O)
- — Z (O)
1910.305 B01
- Issued
- Mar 12, 2001
- Abate by
- Mar 15, 2001
Recent events (2)
- — I (O)
- — Z (O)
More inspections at Industrial Hard Chrome LTD.
View Industrial Hard Chrome LTD.'s full OSHA safety record →
More inspections in this industry (NAICS 000000)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 304154347.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.