CECIL, PA ·
OSHA Inspection: GARY ANDREIS BUILDING & REMODELING
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of GARY ANDREIS BUILDING & REMODELING in 3351 MILLERS RUN ROAD, CECIL, PA 15321 (NAICS 000000). OSHA activity number 304177686.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GARY ANDREIS BUILDING & REMODELING
- Site address
- 3351 MILLERS RUN ROAD
- City
- CECIL
- State
- PA
- ZIP
- 15321
- Mailing
- 115 C WILLIAM STREET, MCDONALD, PA 15057
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (N)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 1541
- Employees
- 2
- Ownership type
- Private (A)
Citations
2 citations on file for this inspection.
5(a)(1)
- Issued
- Jun 5, 2001
- Abate by
- Jun 8, 2001
- Penalty
- Initial $1,500 · Current $1,050 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to being crushed by falling trusses that had not been properly braced: (a) DeFelice's Deli jobsite, 3351 Millers Run Road, Cecil, PA; On May 02, 2001, an employee was injured when he was crushed by falling wooden trusses. These wooden trusses had not been properly braced either laterally nor diagonally nor had the proper amount and sized bracing lumber been used. Among other methods, one feasible and acceptable method to correct this hazard is to Use proper sized lumber for all bracing; Install all lateral and diagonal bracing as required; and Follow the ANSI/Truss Plate Institute Summary Sheet, HIB-91 (Handling, Installation, and Bracing Metal Plate Connected Wooden Trusses) during the erection and installation of all wood truss systems.tion
Recent events (2)
- · F (S) $1050.00
- · Z (S) $1500.00
1926.1053 B01
- Issued
- Jun 5, 2001
- Abate by
- Jun 8, 2001
- Penalty
- Initial $600
Recent events (2)
- · F (S)
- · Z (S) $600.00
More inspections in this industry (NAICS 000000)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 304177686.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.