Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,198,201Inspections Most recent open 2026-08-31 Last loaded 2026-09-03

OSHA Inspection: ORION SAFETY PRODUCTS

Accident-driven inspection · Safety discipline

On , OSHA opened an accident-driven safety inspection of ORION SAFETY PRODUCTS in 2830 ST. MICHAELS ROAD, EASTON, MD 21601 (NAICS 000000). OSHA activity number 304331424.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Orion Safety Products for free Get an email when a new federal OSHA severe-injury report for Orion Safety Products is published. One employer, no account, unsubscribe in one click.
Site address
2830 ST. MICHAELS ROAD
City
EASTON
State
MD
ZIP
21601
Inspection type
Accident-driven (A)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (N)
Opened
Closing conference
Case closed
Data loaded
NAICS code
000000
SIC code (legacy)
2899
Employees
70
Ownership type
Private (A)
Industry flags
Manufacturing safety.

2 citations on file for this inspection.

50104 A

Other-than-serious 2 instances 3 exposed
Issued
Jul 25, 2001
Abate by
Jul 28, 2001
Penalty
Initial $3,000 · Current $1,000 Reduced
Labor and Employment Article, Section 5-104(a):  The employer did not
furnish employment
and a place of employment which were free from recognized hazards that
were causing or
likely to cause death or serious physical harm to employees:
(a)Date of Violation:On or about 03/08/01
Location:Wet Mix Room
Condition:Employees removed combustible flare ignition mixture residues
from
the floor and other surfaces using a ferrous metal floor scraper.
Among other, one feasible and acceptable abatement method to correct this
hazard is to
prohibit the use of any potential ignition producing scraping tools and to
fully cover the floor
using disposable coverings to minimize manual cleaning.
(b)Date of Violation:On or about 03/08/01
Location:Button Fill Room
Condition:Employees removed combustible flare ignition mixture residues
from
the floor and other surfaces using a ferrous metal floor scraper.
Among others, one feasible and acceptable abatement method to correct this
hazard is to
prohibit the use of any potential ignition producing scraping tools and to
fully cover the floor
disposable coverings to minimize manual cleaning.
Abatement documentation (photographs, receipts, copies of programs,
training
certification, etc.) is required for this item.
Recent events (2)
  • · I (O) $1000.00
  • · Z (O) $3000.00

50104 A

Other-than-serious 2 instances 3 exposed
Issued
Jul 25, 2001
Abate by
Jul 28, 2001
Penalty
Initial $3,000 · Current $1,000 Reduced
Labor and Employment Article, Section 5-104(a), Annotated Code of
Maryland:  The
employer did not furnish employment and a place of employment which were
free from
recognized hazards that were causing or likely to cause death or serious
physical harm to
employees:
(a)Date of Violation:On or about 03/08/01
Location:Wet Mix Room
Condition:Building surfaces and equipment had not been vacuumed nor had
other
effective dust reduction means been taken to minimize the residual dust
from the "flare ignition mixture" prior to employees using compressed
air, at approximately 90 p.s.i. from a handheld nozzle, to "blowdown"
the room during cleaning operations.
Among others, one feasible and acceptable abatement method to correct this
hazard is to
follow the requirements of NFPA 654:
vacuum the area and equipment prior to blowdown; shut down or remove
electrical power
and other ignition sources; use only low pressure [15 p.s.i. (103kPa)]
steam or compressed
air to clean; ensure there are no hot surfaces in the area being cleaned
capable of igniting a
dust cloud or layer.
(b)Date of Violation:On or about 03/08/01
Location:Dry Mix Room
Condition:Building surfaces and equipment had not been vacuumed nor had
other
effective dust reduction means been taken to minimize the residual dust
from the "flare ignition mixture" prior to employees using compressed
air, at approximately 90 p.s.i. from a handheld nozzle, to "blowdown"
the room during cleaning operations.
Among others, one feasible and acceptable abatement method to correct this
hazard is to
follow the requirements of NFPA 654:
vacuum the area and equipment prior to blowdown; shut down or remove
electrical power
and other ignition sources; use only low pressure [15 p.s.i. (103kPa)]
steam or compressed
air to clean; ensure there are no hot surfaces in the area being cleaned
capable of igniting a
dust cloud or layer.
Abatement documentation (photographs, receipts, copies of programs,
training
certification, etc.) is required for this item.
Recent events (2)
  • · I (O) $1000.00
  • · Z (O) $3000.00

View Orion Safety Products's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 304331424.