Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,194,531Inspections Most recent open 2026-08-11 Last loaded 2026-08-14

OSHA Inspection: AIR-WAY COMMUNICATIONS

Accident-driven inspection · Safety discipline

On , OSHA opened an accident-driven safety inspection of AIR-WAY COMMUNICATIONS in HWY 1050, UVALDE, TX 78801 (NAICS 000000). OSHA activity number 304392228.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Air-Way Communications for free Get an email when a new federal OSHA severe-injury report for Air-Way Communications is published. One employer, no account, unsubscribe in one click.
Site address
HWY 1050
City
UVALDE
State
TX
ZIP
78801
Mailing
2822 COUNTISS ST, CORPUS CHRISTI, TX 78410
Inspection type
Accident-driven (A)
Scope
Partial (B)
Discipline
Safety
Advance notice
Yes
Union status
Non-union (N)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
000000
SIC code (legacy)
1731
Employees
4
Ownership type
Private (A)
Industry flags
Construction safety.

3 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 4 exposed
Issued
Sep 26, 2002
Abate by
Nov 14, 2002
Penalty
Initial $2,100 · Current $2,100
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees
in that employees
were exposed to:
(a) the hazards of falls in excess of 300 feet (91.4m) at a tower site
located off Hwy.
1050, 2 miles east of Garner State Park in Real county, where an employee
fell on or about 09-
12-02. On that date and prior to at other locations, employees were being
lifted using an electric
cat head (friction) hoist: Deficiencies included, but were not limited to
the following: 1. The
employer permitted employees to ride on a poly dacron rope line that was
wrapped around a cat
head hoist which was connected near the base of the tower. The cat head
was being used as a
friction winch and was not approved for lifting people. The cat head winch
was also lifting coax
cable at the same time in addition to the victim. The load line, which was
1/2 inch poly dacron
rope had a breaking strength of 540 pounds, almost exactly the load of 535
pounds imposed.
One means of abatement among others, is to: Ensure safe work practices
identified
in CPL 2-
1.36, Interim Inspection Procedures During Communication Tower
Construction Activities,
03/26/2002, are complied with at all times.

1926.21 B02

Serious Gravity 10 1 instance 4 exposed
Issued
Sep 26, 2002
Abate by
Oct 23, 2002
Penalty
Initial $2,100 · Current $2,100

1904.8

Other-than-serious Gravity 00 1 instance 4 exposed
Issued
Sep 26, 2002
Abate by
Oct 2, 2002
Penalty
Initial $1,500 · Current $1,500

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 304392228.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.