OSHA Inspection: STRUCTURAL METALS, INC

Accident-driven inspection · Safety discipline

On , OSHA opened an accident-driven safety inspection of STRUCTURAL METALS, INC in STEEL MILL ROAD, SEGUIN, TX 78155 (NAICS 331221). OSHA activity number 304392509.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Structural Metals, INC — free Get an email when a new federal OSHA severe-injury report for Structural Metals, INC is published. One employer, no account, unsubscribe in one click.
Site address
STEEL MILL ROAD
City
SEGUIN
State
TX
ZIP
78155
Inspection type
Accident-driven (A)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Data loaded
NAICS code
331221
SIC code (legacy)
3316
Employees
600
Ownership type
A

1 citation on file for this inspection.

5(a)(1)

Deleted Willful Gravity 10 1 instance 2 exposed
Issued
Dec 4, 2002
Abate by
Dec 16, 2002
Penalty
Initial $70,000 · Current $70,000
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees in that employees
were exposed to the hazards of explosion:
a) On or about September 27, 2002 two employees were burned when the Fuchs
furnace
at the melt shop exploded. The employer allowed the melting process to
continue despite water
leakage that occurs from damaged water cooling panels. This practice
requires the Melter and
or General Turn Foreman to make an assessment to determine the severity of
the leak and the
probability of puddling inside the furnace.  The employees were in the
process of performing
the furnace turn around when water from a leaking roof (cooling) panel
became encapsulated
in the molten metal leading to the explosion and ultimately to critical
burns over 68 and 92
percent of the employees bodies.
Among other methods, one feasible and acceptable abatement method to
correct the hazard is
to repair the damaged cooling panel by welding or replacing the cooling
panel. The employer
can also improve their foamy slag process to coat the sides and roof of
the furnace to reduce the
possibility of damage to the cooling panels.
Recent events (2)