SEGUIN, TX —
OSHA Inspection: STRUCTURAL METALS, INC
Accident-driven inspection · Safety discipline
At a glance
On , OSHA opened an accident-driven safety inspection of STRUCTURAL METALS, INC in STEEL MILL ROAD, SEGUIN, TX 78155 (NAICS 331221). OSHA activity number 304392509.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- STRUCTURAL METALS, INC
- Site address
- STEEL MILL ROAD
- City
- SEGUIN
- State
- TX
- ZIP
- 78155
What kind of inspection was it?
- Inspection type
- Accident-driven (A)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 331221
- SIC code (legacy)
- 3316
- Employees
- 600
- Ownership type
- A
Citations
1 citation on file for this inspection.
5(a)(1)
- Issued
- Dec 4, 2002
- Abate by
- Dec 16, 2002
- Penalty
- Initial $70,000 · Current $70,000
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazards of explosion: a) On or about September 27, 2002 two employees were burned when the Fuchs furnace at the melt shop exploded. The employer allowed the melting process to continue despite water leakage that occurs from damaged water cooling panels. This practice requires the Melter and or General Turn Foreman to make an assessment to determine the severity of the leak and the probability of puddling inside the furnace. The employees were in the process of performing the furnace turn around when water from a leaking roof (cooling) panel became encapsulated in the molten metal leading to the explosion and ultimately to critical burns over 68 and 92 percent of the employees bodies. Among other methods, one feasible and acceptable abatement method to correct the hazard is to repair the damaged cooling panel by welding or replacing the cooling panel. The employer can also improve their foamy slag process to coat the sides and roof of the furnace to reduce the possibility of damage to the cooling panels.
Recent events (2)
- — D (W) $70000.00
- — Z (W) $70000.00
More inspections at Structural Metals, INC
View Structural Metals, INC's full OSHA safety record →
More inspections in this industry (NAICS 331221)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 304392509.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.