CAPE CORAL, FL ·
OSHA Inspection: C.M. DUNCAN CARPENTRY, INC
Accident-driven inspection · Safety discipline
At a glance
On , OSHA opened an accident-driven safety inspection of C.M. DUNCAN CARPENTRY, INC in 3428 S.W. 27TH PLACE, CAPE CORAL, FL 33914 (NAICS 000000). OSHA activity number 304443062.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- C.M. DUNCAN CARPENTRY, INC
- Site address
- 3428 S.W. 27TH PLACE
- City
- CAPE CORAL
- State
- FL
- ZIP
- 33914
- Mailing
- 6867 PENTLAND WAY, #83, FT. MYERS, FL 33912
What kind of inspection was it?
- Inspection type
- Accident-driven (A)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (N)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 1751
- Employees
- 4
- Ownership type
- Private (A)
Citations
5 citations on file for this inspection.
5(a)(1)
- Issued
- Jul 18, 2001
- Abate by
- Jul 26, 2001
- Penalty
- Initial $3,500 · Current $3,150 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazard of falling from the metal plate connected wood roof trusses that were subject to potential movement due to the lack of proper temporary bracing. Employees were also exposed to the hazard of being struck by falling metal plate connected wood roof trusses that may experience movement, and/or collapse, due to the lack of proper temporary bracing: a) At the construction site of the single family home located at 3428 S.W. 27th Place, Cape Coral, Florida. The metal plate connected wood roof trusses which were installed, on or about 4/12/01, were not installed with the proper required temporary bracing. Short 1x3 inch and 2x4 inch "spacer" pieces of lumber were used between adjacent trusses for spacing and temporary bracing. Light gage metal "spacers" (Hughes "TS" Truss Spacers) were used as spacers and temporary spacing. The top chords of the roof trusses were not provided with the proper required lateral and diagonal temporary bracing. One feasible and acceptable abatement method to correct these hazards is to install the roof trusses in accordance the Truss Plate Institutes recommendations which are contained in "HIB- 91, Recommendations For Handling, Installing and Bracing Metal Plate Connected Wood Trusses". The truss manufacturer provides a copy of the "HIB-91 Summary Sheet" with the delivery of the truss information and their Design Criteria refers to the HIB-91 for proper handling, installing and bracing. The Standard Building Code also refers to the HIB-91 for handling, installing and bracing of metal plate connected wood trusses. DOCUMENTED ABATEMENT VERIFICATION IS REQUIRED FOR THIS ITEM.
Recent events (2)
- · I (S) $3150.00
- · Z (S) $3500.00
1926.501 B13
- Issued
- Jul 18, 2001
- Abate by
- Jul 26, 2001
- Penalty
- Initial $4,900
Recent events (2)
- · I (S)
- · Z (S) $4900.00
1926.503 A01
- Issued
- Jul 18, 2001
- Abate by
- Jul 26, 2001
- Penalty
- Initial $4,900
Recent events (2)
- · I (S)
- · Z (S) $4900.00
1926.501 B13
- Issued
- Jul 18, 2001
- Abate by
- Jul 26, 2001
- Penalty
- Current $4,410
Recent events (3)
- · Q $4410.00
- · I (S) $4410.00
- · Z (S) $4410.00
1926.503 A01
- Issued
- Jul 18, 2001
- Abate by
- Jul 26, 2001
Recent events (2)
- · I (S)
- · Z (S)
More inspections in this industry (NAICS 000000)