Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CHESTERFIELD STEEL SERVICE

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of CHESTERFIELD STEEL SERVICE in 1220 E. 222ND STREET, EUCLID, OH 44117 (NAICS 000000). OSHA activity number 304483316.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Chesterfield Steel Service — free Get an email when a new federal OSHA severe-injury report for Chesterfield Steel Service is published. One employer, no account, unsubscribe in one click.
Site address
1220 E. 222ND STREET
City
EUCLID
State
OH
ZIP
44117
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Y
Opened
Closing conference
Case closed
Data loaded
NAICS code
000000
SIC code (legacy)
3499
Employees
75
Ownership type
A
Industry flags
Construction safety.

4 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 75 exposed
Issued
Sep 5, 2001
Abate by
Sep 18, 2001
Penalty
Initial $2,500 · Current $1,000 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees in that employees
were exposed to:
On and prior to July 18, 2001, employees were exposed to serious injuries
while handling coils
of steel.  Employee/laborers involved with the rebanding of steel coils
were doing so
inappropriately at their own discretion, by not following the established
written procedure which
dictates in detail how banding of coils will be accomplished.
During the inspection it was evident that employees have not been
adequately trained to reband
coils of steel properly.  There is a serious propensity for injury to
occur, since the current
rebanding methods are improvisational.  It was established that the
employer is not enforcing
strict adherence to the written banding procedures in place.
Among other methods, the following are feasible and acceptable methods to
minimize the
probability of injury during the handling of steel coils.
1.  Develop safe banding procedures which list the sequence of operations,
particularly during
the rebanding operations following the filling of "cut to order" tasks.
2.  Train all effected employees on the requirements set forth in the
procedures and related
safety precautions including the importance of properly positioning one's
self in relation to the
coil, particularly when initially lifting a coil off the floor which
subjects the coil's bands to more
force than when resting on the floor.
3.  Enforce employee use of the procedures.
4.  Follow ANSI B11.18-1992 recommendations for proper banding which are
as included
but not limited to the following.
a. Banding material should be a minimum of 1 and 1/4 inch wide by .031
inches thick
and heat treated.
b. All banding seals should be double crimped.
c. Corner protectors should be used on all bands placed through the eye of
the coil.
They should be sufficient enough to protect against rupture of the band
due to the sharp edges
of the material or too acute of a bend.
d. A minimum of 3 bands (equally spaced) should be placed through the eye
of the coil.
e. Bands should be placed on the circumference of the coil as appropriate
for the size,
gage and grade of metal.
5.  Develop and implement safe placement procedures for banded coils in
order to prevent
damage and/or corrosion to the banding clips.
6.  Develop and implement safe procedures for banded coils in order to
prevent
undue stresses
on the bands of the bottom coils.
Recent events (2)
  • — F (S) $1000.00
  • — Z (S) $2500.00

1910.176 B

Serious Gravity 10 1 instance 75 exposed
Issued
Sep 5, 2001
Abate by
Sep 18, 2001
Penalty
Initial $2,500 · Current $1,000 Reduced
Recent events (2)
  • — F (S) $1000.00
  • — Z (S) $2500.00

1910.179 N04 II

Serious Gravity 10 1 instance 75 exposed
Issued
Sep 5, 2001
Abate by
Sep 13, 2001
Penalty
Initial $2,500 · Current $1,000 Reduced
Recent events (2)
  • — F (S) $1000.00
  • — Z (S) $2500.00

1910.178 Q07

Other-than-serious Gravity 01 1 instance 75 exposed
Issued
Sep 5, 2001
Abate by
Sep 13, 2001
Recent events (2)
  • — F (O)
  • — Z (O)

View Chesterfield Steel Service's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 304483316.