ROSEMONT, IL ·
OSHA Inspection: J.D. BRAKE & CLUTCH CO., INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of J.D. BRAKE & CLUTCH CO., INC. in 9994 BRYN MAWR AVENUE, ROSEMONT, IL 60018 (NAICS 000000). OSHA activity number 304492853.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- J.D. BRAKE & CLUTCH CO., INC.
- Site address
- 9994 BRYN MAWR AVENUE
- City
- ROSEMONT
- State
- IL
- ZIP
- 60018
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (N)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 3714
- Employees
- 3
- Ownership type
- Private (A)
Citations
3 citations on file for this inspection.
5(a)(1)
- Issued
- Jun 8, 2001
- Abate by
- Jul 5, 2001
- Penalty
- Initial $750 · Current $375 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to laceration/amputation hazards: (a) Shop Area- Provisions were not made to prevent industrial machinery, including but not limited to, the Toledo and the Jet vertical band saws from automatically restarting upon restoration of power after a power source failure; and the motor starters were not protected against unexpected or accidental activation (had toggle switches). Among others, one method of abatement is to equip the machinery with an electrical device that is designed to prevent automatic restart after power has been restored to require operating levels; and to install and utilize a starter controls that would prevent unexpected or accidental activation, as prescribed in NFPA-79, Electrical Standard for Industrial Machinery, Section 8. Abatement documentation is required for this item in accordance with 29 CFR 1903.19 paragraph (d).
Recent events (2)
- · I (S) $375.00
- · Z (S) $750.00
1910.212 A01
- Issued
- Jun 8, 2001
- Abate by
- Jul 5, 2001
- Penalty
- Initial $750 · Current $375 Reduced
Recent events (2)
- · I (S) $375.00
- · Z (S) $750.00
1910.219 M01 I
- Issued
- Jun 8, 2001
- Abate by
- Jul 5, 2001
More inspections at J.D. Brake & Clutch CO., INC.
View J.D. Brake & Clutch CO., INC.'s full OSHA safety record →
More inspections in this industry (NAICS 000000)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 304492853.