Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: BECON CONSTRUCTION, CO.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of BECON CONSTRUCTION, CO. in 976 C.R. ROAD 4213, DEWEYVILLE, TX 77614 (NAICS 236210). OSHA activity number 304511181.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Becon Construction, CO. — free Get an email when a new federal OSHA severe-injury report for Becon Construction, CO. is published. One employer, no account, unsubscribe in one click.
Site address
976 C.R. ROAD 4213
City
DEWEYVILLE
State
TX
ZIP
77614
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Data loaded
NAICS code
236210
SIC code (legacy)
1531
Employees
20000
Ownership type
A

1 citation on file for this inspection.

5(a)(1)

Serious Gravity 10 2 instances 4 exposed
Issued
Mar 12, 2003
Abate by
Apr 7, 2003
Penalty
Initial $7,000 · Current $7,000
Section 5 (a) (1) of the Occupational Safety and Health Act of 1970: The
employer did not
furnish employment and a place of employment which were free from
recognized hazards
that were causing or likely to cause death or physical harm to employees
in that employees
were exposed to:
(a)Serious burns from steam release,where on or about December 6, 2002,
company was  preforming Turbine Trip Test in the 1AA01-07 piping system at
the Cottonwood Power Project. Two employees received serious burns to the
hands , face and arms.The release was due to a missing gasket in the
system.
Reference: ANSI B31.1-1977 Edition-for Gaskets, in section 108.4. Company
did not follow the guidelines in this paragraph.
(b)Company did not follow the industry practice of evacuating the area of
all non-
essential personnel when start-up testing is performed. This company
acknowledged the policy, but did not follow it.Reference: Accident
Prevention
Manual for Industrial Operations 7th. Edition page 1405. The two seriously
injured employees were not required to be in the area to assist in the
testing.
Among others, one feasible and acceptable method to correct the hazard is
the development
and implementation of the following:
(a)Employees not required for testing procedures should be evacuated from
area
prior to test.
(b)Warning systems, such as horns, should be used to warn employees prior
to
testing.
(c)Foreman should monitor the operation to assure that employees have
evacuated
the area prior to test.
(d)Employees  should be trained on the warning systems.
(e)Develop procedure for verification that the various combination of
flange
materials, the selection of bolting materials and related rules concerning
flange
faces and gaskets conforms to the requirements listed in Table 108.5.2 of
ANSI B31.1-1977 Edition.
*** Certification and Documentation of Abatement Required ***
Recent events (2)
  • — I (S) $7000.00
  • — Z (S) $7000.00

View Becon Construction, CO.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 304511181.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.