BROOKLYN, NY —
OSHA Inspection: HALL STREET COLD STORAGE WAREHOUSES, INC.
Accident-driven inspection · Safety discipline
At a glance
On , OSHA opened an accident-driven safety inspection of HALL STREET COLD STORAGE WAREHOUSES, INC. in 38 HALL STREET, BROOKLYN, NY 11205 (NAICS 000000). OSHA activity number 304520570.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- HALL STREET COLD STORAGE WAREHOUSES, INC.
- Site address
- 38 HALL STREET
- City
- BROOKLYN
- State
- NY
- ZIP
- 11205
- Mailing
- 12 HALL STREET, BROOKLYN, NY 11205
What kind of inspection was it?
- Inspection type
- Accident-driven (A)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Y
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 4222
- Employees
- 29
- Ownership type
- A
- Industry flags
- Manufacturing safety.
Citations
8 citations on file for this inspection.
1910.30 A03
- Issued
- Dec 18, 2001
- Abate by
- Dec 31, 2001
- Penalty
- Initial $1,250 · Current $400 Reduced
Recent events (2)
- — I (S) $400.00
- — Z (S) $1250.00
1910.36 B04
- Issued
- Dec 18, 2001
- Abate by
- Dec 21, 2001
- Penalty
- Initial $1,250 · Current $400 Reduced
Recent events (2)
- — I (S) $400.00
- — Z (S) $1250.00
1910.37 Q02
- Issued
- Dec 18, 2001
- Abate by
- Dec 21, 2001
- Penalty
- Initial $1,250 · Current $400 Reduced
Recent events (2)
- — I (S) $400.00
- — Z (S) $1250.00
1910.151 C
- Issued
- Dec 18, 2001
- Abate by
- Dec 31, 2001
- Penalty
- Initial $2,500 · Current $500 Reduced
Recent events (2)
- — I (S) $500.00
- — Z (S) $2500.00
1910.157 C01
- Issued
- Dec 18, 2001
- Abate by
- Dec 21, 2001
- Penalty
- Initial $1,000 · Current $400 Reduced
Recent events (2)
- — I (S) $400.00
- — Z (S) $1000.00
1910.178 L
- Issued
- Dec 18, 2001
- Abate by
- Dec 31, 2001
- Penalty
- Initial $1,750 · Current $400 Reduced
Recent events (2)
- — I (S) $400.00
- — Z (S) $1750.00
1910.303 G02 I
- Issued
- Dec 18, 2001
- Abate by
- Dec 31, 2001
- Penalty
- Initial $1,250 · Current $500 Reduced
Recent events (2)
- — I (S) $500.00
- — Z (S) $1250.00
5(a)(1)
- Issued
- Dec 18, 2001
- Abate by
- Dec 31, 2001
- Penalty
- Initial $28,000 · Current $13,000 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to: the hazard of falling in the freight elevator shaftway due to the fact that the hoistway door interlocks were inoperative as a result of being bypassed: Location: 12-38 Hall Street, Brooklyn, N.Y. On or about June 25, 2001 a)Building 2: Small Freight Elevator - An employee fell to his death through the elevator shaftway which was not guarded,from the 6th floor to the top of the elevator cab located on the 3rd floor. 1.Interior of the elevator: The rear/back gate switch was blocked with a piece of wood and the front gate switch was duct-taped closed so that the elevator could operator/run with the doors in the open position. 2.Elevator room: A clip jumper was attached to the terminals on the control which allowed the hoistway door interlocks to be jumped and/or the doors of the elevator to be in the open position while the elevator was running. Among other methods, one feasible and acceptable method to correct this hazard is to comply with the American National Standard Safety Code for Elevator Dumbwaiters Escalators and Moving Walks stipulated by the American National Standards Institute (ANSI) - ANSI A17.1971. Among other methods, one feasible and acceptable means of abatement to correct the hazard, are, but not limited to the following: 1.Section 1002 - Maintenance, Rule 1002.4 - Making Safety Devices Inoperative: No person shall at any time make any required safety device or electrical protective device inoperative, except where necessary during tests, inspections, and maintenance, such devices shall be restored to their normal operating condition in conformity with the applicable requirements (See Rule 210.7). 2.Inspect all elevators interlocks and/or gate switches on a daily basis for material, devices or objects used to bypass the interlocks and remove items found. 3. Instruct Employees on the dangers of bypassing the elevator interlocks. 4.Install and repair shaftway door interlocks/switches bypassed. 5.Enforce and comply with ANSI A17.1-1971 and/or ASME A17.3-1993,1996. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT VERIFICATION FOR THIS ITEM. FAILURE TO SUBMIT ABATEMENT VERIFICATION WILL RESULT IN AN ADDITIONAL $1000.00 PENALTY IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
- — I (W) $13000.00
- — Z (W) $28000.00
More inspections at Hall Street Cold Storage Warehouses, INC.
View Hall Street Cold Storage Warehouses, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 000000)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 304520570.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.