BRENTWOOD, NH —
OSHA Inspection: SWAIN PLUMBING & HEATING, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of SWAIN PLUMBING & HEATING, INC. in WINDSOR MEADOWS, BRENTWOOD, NH 03077 (NAICS 238220). OSHA activity number 304562093.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SWAIN PLUMBING & HEATING, INC.
- Site address
- WINDSOR MEADOWS
- City
- BRENTWOOD
- State
- NH
- ZIP
- 03077
- Mailing
- 507 RAYMOND RD., CANDIA, NH 03034
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238220
- SIC code (legacy)
- 1711
- Employees
- 3
- Ownership type
- A
Citations
4 citations on file for this inspection.
5(a)(1)
- Issued
- Jan 20, 2004
- Abate by
- Feb 24, 2004
- Penalty
- Initial $750 · Current $750
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to hazards such as but not limited to asphyxiation, fire, and explosion, resulting due to entry into an unknown atmosphere in a confined space. a.Windsor Meadows complex, Bldg. 5, Brentwood, NH - On 07/23/03 an employee of Swain Plumbing & Heating entered a confined space, the lower level of the "doghouse" utility annex, which had not been assessed for potential hazards. Two employees of Tri-State Sprinklers and one of Swain Plumbing & Heating received burns due to a propane explosion in this space. The lower level was accessible only by a ladder and met the definition of a confined or enclosed space (1926.21(b)(6)(ii)). Abatement note: One feasible method of abatement, among others, is to develop and implement a confined space program including the elements outlined in American National Standard Institute (ANSI), standard Z117.1 (Safety Requirements for Confined Spaces). Such a program would include but not be limited to training in the recognition of and safe entry into confined spaces; procedures for atmospheric testing for flammable, toxic, or oxygen deficient atmospheres prior to and/or during employee entries; appropriate ventilation methods to controlled detected atmospheric hazards; appropriate respiratory protection where the hazards can not be controlled by ventilation.
1926.21 B06 I
- Issued
- Jan 20, 2004
- Abate by
- Feb 24, 2004
1926.350 B04
- Issued
- Jan 20, 2004
- Abate by
- Jan 23, 2004
2150
1926.353 B01
- Issued
- Jan 20, 2004
- Abate by
- Jan 23, 2004
More inspections in this industry (NAICS 238220)
More inspections in NH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 304562093.