CAMDEN, NY —
OSHA Inspection: OWI WIRE PLANT
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of OWI WIRE PLANT in HARDEN BLVD., CAMDEN, NY 13316 (NAICS 000000). OSHA activity number 304588098.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- OWI WIRE PLANT
- Site address
- HARDEN BLVD.
- City
- CAMDEN
- State
- NY
- ZIP
- 13316
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 3496
- Employees
- 76
- Ownership type
- A
Citations
1 citation on file for this inspection.
5(a)(1)
- Issued
- Dec 18, 2001
- Abate by
- Dec 21, 2001
- Penalty
- Initial $2,125 · Current $1,063 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employmnent and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to THE HAZARD OF BEING STRUCK-BY FALLING OBJECTS: a)760 Kinrei Area, on or about 11/16/2001, the following overhead hoists had a non-functioning safety mechanism: 1.Hoist # 2, 760 Kinrei area, a 635 Lodestar, CM Series 1 ton overhead hoist had a non-functioning upper and lower limit switch mechanism. Among other methods, several feasible and acceptable abatement methods to correct this hazard are to: 1.Repair or replace the upper and lower limit switch mechanism. 2.Conduct frequent and periodic inspections of the hoists in accordance with ANSI B30.16, 1973 Overhead Hoists.
Recent events (2)
- — I (S) $1062.50
- — Z (S) $2125.00
More inspections at OWI Wire Plant
View OWI Wire Plant's full OSHA safety record →
More inspections in this industry (NAICS 000000)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 304588098.