LITTLE FALLS, NY —
OSHA Inspection: FELDMEIER EQUIPMENT INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of FELDMEIER EQUIPMENT INC. in 575 E. MILL STREET, LITTLE FALLS, NY 13365 (NAICS 000000). OSHA activity number 304591522.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FELDMEIER EQUIPMENT INC.
- Site address
- 575 E. MILL STREET
- City
- LITTLE FALLS
- State
- NY
- ZIP
- 13365
- Mailing
- P.O. BOX 1028, LITTLE FALLS, NY 13365
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 3443
- Employees
- 138
- Ownership type
- A
- Industry flags
- Manufacturing safety.
Citations
12 citations on file for this inspection.
5(a)(1)
- Issued
- Jul 24, 2002
- Abate by
- Jul 29, 2002
- Penalty
- Initial $1,875 · Current $1,875
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to THE HAZARD OF BEING STRUCK-BY THE LOAD : a)North end of the New Tank Shop, on or about 06/19/2002: A Spreader beam, 12 foot long, with a lifting chain affixed to each end which had been locally designed and fabricated as a below-the-hook lifting device had no rated load markings and no inspections or external code mark record(s) was used to evaluate external conditions. b)Seam Welding Area, on or about 06/19/2002: A Spreader beam, 21 foot long pipe 4 1/2 inches in diameter, with three lifting chains affixed at the bottom and one lifting chain at the top which had been locally designed and fabricated as a below-the-hook lifting device had no rated load markings and no inspections or external code mark record(s) was used to evaluate external conditions. c)Circle Shear, on or about 06/19/2002: Two Spreader beams, one 12 foot long and one 8 foot long both 4 inch square hollow tubes, with lifting chains attached to each end which had been locally designed and fabricated as below-the-hook lifting devices had no rated load markings and no inspections or external code mark record(s) was used to evaluate external conditions. Among other methods, feasible and acceptable methods to correct each of these hazards are to: 1.Rate and mark the load capacity of the lifting devices on a tag/plate or equivalent. Section 20-1, ANSI/ASME B30.20-1993, Below-the-Hook Lifting Devices. 2.Conduct frequent and periodic inspections of the lifting device in accordance with Section 20-1, ANSI/ASME B30.20-1993, Below-the-Hook Lifting Devices.
Recent events (2)
- — J (S) $1875.00
- — Z (S) $1875.00
1910.23 C01
- Issued
- Jul 24, 2002
- Abate by
- Aug 26, 2002
- Penalty
- Initial $1,875 · Current $1,875
Recent events (2)
- — J (S) $1875.00
- — Z (S) $1875.00
1910.107 B09
- Issued
- Jul 24, 2002
- Abate by
- Aug 26, 2002
- Penalty
- Initial $1,500
Recent events (2)
- — J (S)
- — Z (S) $1500.00
1910.107 F03
- Issued
- Jul 24, 2002
- Abate by
- Aug 26, 2002
Recent events (2)
- — J (S)
- — Z (S)
1910.107 G02
- Issued
- Jul 24, 2002
- Abate by
- Aug 26, 2002
Recent events (2)
- — J (S)
- — Z (S)
1910.134 B03
- Issued
- Jul 24, 2002
- Abate by
- Aug 1, 2002
- Penalty
- Initial $1,875 · Current $1,875
Recent events (2)
- — J (S) $1875.00
- — Z (S) $1875.00
1910.134 B05
- Issued
- Jul 24, 2002
- Abate by
- Aug 1, 2002
Recent events (2)
- — J (S)
- — Z (S)
1910.134 B10
- Issued
- Jul 24, 2002
- Abate by
- Aug 1, 2002
Recent events (2)
- — J (S)
- — Z (S)
1910.134 C01
- Issued
- Jul 24, 2002
- Abate by
- Aug 1, 2002
Recent events (2)
- — J (S)
- — Z (S)
1910.134 G01 IA
- Issued
- Jul 24, 2002
- Abate by
- Aug 1, 2002
Recent events (2)
- — J (S)
- — Z (S)
1910.184 E03 I
- Issued
- Jul 24, 2002
- Abate by
- Jul 29, 2002
- Penalty
- Initial $1,875 · Current $1,875
Recent events (2)
- — J (S) $1875.00
- — Z (S) $1875.00
1910.184 E03 II
- Issued
- Jul 24, 2002
- Abate by
- Jul 29, 2002
Recent events (2)
- — J (S)
- — Z (S)
More inspections at Feldmeier Equipment INC.
View Feldmeier Equipment INC.'s full OSHA safety record →
More inspections in this industry (NAICS 000000)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 304591522.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.