ELIZABETH, NJ —
OSHA Inspection: CSI BUILDERS INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of CSI BUILDERS INC. in 1000 KAPKOWSKI AVE., ELIZABETH, NJ 07202 (NAICS 000000). OSHA activity number 304727217.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CSI BUILDERS INC.
- Site address
- 1000 KAPKOWSKI AVE.
- City
- ELIZABETH
- State
- NJ
- ZIP
- 07202
- Mailing
- PO BOX 645, WAYNE, NJ 07474
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Y
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 1741
- Employees
- 55
- Ownership type
- A
- Industry flags
- Construction safety.
Citations
3 citations on file for this inspection.
5(a)(1)
- Issued
- Jan 24, 2003
- Abate by
- Jan 29, 2003
- Penalty
- Initial $2,500 · Current $1,700 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to a scaffold collapse. a) 1000 Kapkowski Ave. Elizabeth NJ. CSI Builders Inc. employees were exposed to the recognized hazard of scaffold collapse and subsequent falls in that the scaffold was not erected or dismantled according to the manufacturer's requirements. This condition resulted in a collapse of the scaffold and serious injury of three workers on or about 12/3/02. One feasible and acceptable method to abate this condition is to is to follow the manufacturer's printed instructions and training instructions as follows: 1. Install ties to the building at designated intervals and specifically on the third mast section 10' to 15' above grade. 2. Add and remove platform extensions only while the platform is at the five-foot level and the second to last tie is installed. 3. Remove workers from platform prior to removing the second to last tie and prior to adding or removing platform extensions. 4. Remove the second to last tie only when the mast is supported by a crane or forklift.
Recent events (2)
- — I (S) $1700.00
- — Z (S) $2500.00
1926.451 F07
- Issued
- Jan 24, 2003
- Abate by
- Jan 29, 2003
- Penalty
- Initial $2,500 · Current $1,650 Reduced
Recent events (2)
- — I (S) $1650.00
- — Z (S) $2500.00
1926.454 B02
- Issued
- Jan 24, 2003
- Abate by
- Jan 29, 2003
- Penalty
- Initial $2,500 · Current $1,650 Reduced
Recent events (2)
- — I (S) $1650.00
- — Z (S) $2500.00
More inspections in this industry (NAICS 000000)
More inspections in NJ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 304727217.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.