Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: COOPER INDUSTRIES, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of COOPER INDUSTRIES, INC. in 4758 WASHINGTON ST., LA GRANGE, NC 28551 (NAICS 000000). OSHA activity number 304741358.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Cooper Industries, INC. — free Get an email when a new federal OSHA severe-injury report for Cooper Industries, INC. is published. One employer, no account, unsubscribe in one click.
Site address
4758 WASHINGTON ST.
City
LA GRANGE
State
NC
ZIP
28551
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Data loaded
NAICS code
000000
SIC code (legacy)
3069
Employees
18438
Ownership type
A
Industry flags
Manufacturing safety.

9 citations on file for this inspection.

95012901

Serious 4 instances 7 exposed
Issued
Nov 7, 2001
Abate by
Dec 5, 2001
Penalty
Initial $1,400 · Current $1,120 Reduced
North Carolina General Statute 95-129(1) of the Occupational Safety and
Health Act of North Carolina:  The employer
did not furnish to each of his employees  conditions of employment and a
place of employment free from recognized
hazards that were causing or likely to cause death or serious physical
harm to employees, in that employees were
exposed to a crushing or struck-by hazard:
A latch was not provided to bridge the throat opening of the hook for the
purpose of retaining slings, chains, etc.,
under slack conditions (ref. ANSI B30.16-1981 Sec 16-1.2.9):
Frequent visual examinations of all functional operating mechanisms for
misadjustment interfering with proper
operation, deformed, chemically damaged, or cracked hooks, hook latches,
and hoist load chain by the operator or
other designated personnel, with records not required, were not performed
on a monthly basis for hoist used under
normal service (ref. ANSI B30.16-1981 Sec 16-2.1.2):
a)Testing area - safety latch and frequent inspections was not provided
for 1/2 Ton, Coffing Chain Hoist,
used to lift 365-580 lb. Test Racks, loaded with cables.
One feasible and acceptable method of abatement, among others, to correct
this hazard is to have a
certified crane company to install a safety latch on appropriate hook;
have designated and qualified
person to perform frequent inspections of the hoists to ensure compliance
with applicable provisions of
this standard.
b) Dept. 903, Shore Power - frequent inspections not performed on 2-Ton,
Load Star Chain Hoist, used
to lift 3,200 lb. lid of Hydro-Tank.
One feasible and acceptable method of abatement, among others, to correct
this hazard is to have a
designated and qualified person to perform frequent inspections of this
hoist to ensure compliance with
applicable provisions of this standard.
c)Molded Set-Up area - frequent inspections not performed on 1-Ton, Budget
Chain Hoist, used to lift
top half of molds, weighing 600 lbs., for the installation of part numbers.
One feasible and acceptable method of abatement, among others, to correct
this hazard is to have a
designated and qualified person to perform frequent inspections of this
hoist to ensure compliance with
applicable provisions of this standard.
Recent events (2)
  • — I (S) $1120.00
  • — Z (S) $1400.00

7F0102

Deleted Serious 5 instances 20 exposed
Issued
Nov 7, 2001
Abate by
Dec 5, 2001
Penalty
Initial $1,400
Recent events (2)
  • — I (S)
  • — Z (S) $1400.00

1910.147 C04 II

Deleted Serious 2 instances 4 exposed
Issued
Nov 7, 2001
Abate by
Nov 13, 2001
Penalty
Initial $700
Recent events (2)
  • — I (S)
  • — Z (S) $700.00

1910.212 A01

Serious 42 instances 58 exposed
Issued
Nov 7, 2001
Abate by
Dec 27, 2001
Penalty
Initial $2,000 · Current $1,600 Reduced
Recent events (2)
  • — I (S) $1600.00
  • — Z (S) $2000.00

1910.215 A04

Serious 1 instance 4 exposed
Issued
Nov 7, 2001
Abate by
Nov 13, 2001
Penalty
Initial $1,000 · Current $800 Reduced
Recent events (2)
  • — I (S) $800.00
  • — Z (S) $1000.00

7F0102

Other-than-serious 3 instances 30 exposed
Issued
Nov 7, 2001
Abate by
Dec 5, 2001

1910.133 A01

Deleted Other-than-serious 1 instance 2 exposed
Issued
Nov 7, 2001
Abate by
Dec 5, 2001
Recent events (2)
  • — I (O)
  • — Z (O)

1910.138 A

Deleted Other-than-serious 1 instance 2 exposed
Issued
Nov 7, 2001
Abate by
Nov 13, 2001
Recent events (2)
  • — I (O)
  • — Z (O)

1910.243 B02

Deleted Other-than-serious 1 instance 6 exposed
Issued
Nov 7, 2001
Abate by
Nov 13, 2001
Recent events (2)
  • — I (O)
  • — Z (O)

View Cooper Industries, INC.'s full OSHA safety record →