Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,549Inspections Most recent open 2026-08-27 Last loaded 2026-08-31

OSHA Inspection: THE ALSTON GROUP

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of THE ALSTON GROUP in 248 DEPOT STREET, ANTIOCH, IL 60002 (NAICS 000000). OSHA activity number 304955883.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch The Alston Group for free Get an email when a new federal OSHA severe-injury report for The Alston Group is published. One employer, no account, unsubscribe in one click.
Establishment
THE ALSTON GROUP
Site address
248 DEPOT STREET
City
ANTIOCH
State
IL
ZIP
60002
Mailing
248 DEPOT STREET, ANTIOCH, IL 60002
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (N)
Opened
Closing conference
Case closed
Data loaded
NAICS code
000000
SIC code (legacy)
3714
Employees
6
Ownership type
Private (A)

4 citations on file for this inspection.

5(a)(1)

Serious Gravity 02 2 instances 6 exposed
Issued
Dec 27, 2001
Abate by
Feb 14, 2002
Penalty
Initial $300 · Current $300
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees in that employees
were exposed to:
Shop area - the DoAll metal cutting band saw was not equipped with a
magnetic restarter or
similar device, as prescribed by the American National Standard for Metal
Cutting Saws, ANSI
B11.10-1990, Section 5.2.3.4, that in the event of an interruption in the
electrical supply, would
prevent the saw from restarting automatically when power is restored; and,
the saw was
equipped with an unprotected, toggle-type, motor starter switch instead of
a starter switch that
was located, designed, constructed, interlocked, or guarded to protect
against unintended
operation as prescribed by the American National Standard for Metal
Cutting band saws, ANSI
B11.10-1990, Section 5.2.3.1.
Abatement certification only is required for this item in accordance with
the
requirements of 29 CFR 1903.19(c).s

1910.303 G02 I

Other-than-serious Gravity 01 2 instances 6 exposed
Issued
Dec 27, 2001
Abate by
Feb 14, 2002

1910.305 B01

Other-than-serious Gravity 01 1 instance 6 exposed
Issued
Dec 27, 2001
Abate by
Feb 14, 2002

1910.305 G02 III

Other-than-serious Gravity 01 1 instance 6 exposed
Issued
Dec 27, 2001
Abate by
Feb 14, 2002