ORLANDO, FL ·
OSHA Inspection: ANDERSON FIRE SPRINKLERS, INC.
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of ANDERSON FIRE SPRINKLERS, INC. in 7684 VINELAND AVE, ORLANDO, FL 32821 (NAICS 000000). OSHA activity number 304957491.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ANDERSON FIRE SPRINKLERS, INC.
- Site address
- 7684 VINELAND AVE
- City
- ORLANDO
- State
- FL
- ZIP
- 32821
- Mailing
- 309 SWEETWATER CLUB CIRCLE, LONGWOOD, FL 32779
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 1711
- Employees
- 6
- Ownership type
- A
Citations
1 citation on file for this inspection.
5(a)(1)
- Issued
- Jul 31, 2002
- Abate by
- Sep 2, 2002
- Penalty
- Initial $300 · Current $300
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970. The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazard of being pulled into and crushed by the rotating parts of a pipe threading machine: (a)Regency Village Publix, Employees operated a Rigid 300 pipe threading machine which was activated by a toggle switch that would not automatically shut the machine off if the operator was inadvertently caught up in its rotating parts. ABATEMENT NOTES: Among other methods, one feasible method to reduce this hazard is to install a properly guarded momentary contact (deadman) foot switch to control the power input into the machine, as stipulated in the American National Standard for pipe tools (ANSI B20B.1- 1982).
More inspections in this industry (NAICS 000000)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 304957491.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.