Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: JACK RUSSELL TOURING, INC.

Accident-driven inspection · Safety discipline

On , OSHA opened an accident-driven safety inspection of JACK RUSSELL TOURING, INC. in 211 COWESETT AVENUE, WEST WARWICK, RI 02893 (NAICS 711130). OSHA activity number 304991243.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Jack Russell Touring, INC. — free Get an email when a new federal OSHA severe-injury report for Jack Russell Touring, INC. is published. One employer, no account, unsubscribe in one click.
Site address
211 COWESETT AVENUE
City
WEST WARWICK
State
RI
ZIP
02893
Mailing
1801 CENTURY PARK EAST 24TH FLOOR, LOS ANGELES, CA 90067
Inspection type
Accident-driven (A)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
711130
SIC code (legacy)
7929
Employees
8
Ownership type
A

1 citation on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 6 exposed
Issued
Aug 18, 2003
Abate by
Aug 21, 2003
Penalty
Initial $7,000 · Current $7,000
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees in that employees
were exposed to the hazard of fire/fire by-products:
a.Site - Employees were exposed to the hazards posed by fire and
by-products of
combustion in that pyrotechnics were used in the establishment where the
following precautions were not taken on or about February 20, 2003:
- Unused pyrotechnic materials were not stored at least 50 feet from
unprotected
heat sources, namely the ignited gerbs*.
- A plan for the use of pyrotechnics had not been developed.
- A walkthrough and a representative demonstration of the pyrotechnics had
not
been conducted.
- All pyrotechnic operators were not licensed nor approved as required.
- Two or more fire extinguishers were not readily accessible while the
pyrotechnics were being loaded, prepared for firing, and fired.
- Personnel who have a working knowledge of fire extinguishers were not
present
while the pyrotechnics were being handled and used.
- Pyrotechnic devices were not mounted such that fallout from the device
would
not endanger human lives or result in personal injury.
- Each pyrotechnic device was not separated from the audience by at minimum
15 feet (but not less than twice the fallout radius of the device).
- Smoking was not prohibited within 25 feet of the area where pyrotechnics
were
being handled or fired.
*Gerb:  A cylindrical preload intended to produce a controlled spray of
sparks with a
reproducible and predictable duration, height, and diameter.
ABATEMENT NOTE:  Among other methods, one feasible and acceptable means of
abatement
would have been to comply with the requirements of NFPA 1126 - Use of
Pyrotechnics before
a Proximate Audience.
Recent events (2)
  • — F (S) $7000.00
  • — Z (S) $7000.00