Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MIDWAY COOP ASSN., MANKATO BRANCH

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of MIDWAY COOP ASSN., MANKATO BRANCH in 901 N. COMMERCIAL, MANKATO, KS 66956 (NAICS 000000). OSHA activity number 305025595.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Midway Coop Assn., Mankato Branch — free Get an email when a new federal OSHA severe-injury report for Midway Coop Assn., Mankato Branch is published. One employer, no account, unsubscribe in one click.
Site address
901 N. COMMERCIAL
City
MANKATO
State
KS
ZIP
66956
Mailing
BOX 383, MANKATO, KS 66956
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
000000
SIC code (legacy)
5153
Employees
4
Ownership type
A

1 citation on file for this inspection.

5(a)(1)

Repeat Gravity 02 2 instances 2 exposed
Issued
Apr 2, 2002
Abate by
Apr 26, 2002
Penalty
Initial $2,400 · Current $1,800 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees in that employees
were exposed to struck by hazards.
The cage type special purpose elevator (man lift) used at the grain
elevator was not equipped
with an enclosure at the following locations of at lest seven feet.
Employees exposed to fall
hazards.
a)Distributor level - thirty-two inch (32") square with post/track for man
lift on
east/west sides.
b)Midlevel - gate thirty-four and one-half inch (34 1/2") long, opening
between
posts forty-two (42") inches wide.
Among other methods, one feasible and acceptable abatement method to
correct
this hazard
is:
Where the hoistway is adjacent to areas permitting passage of people
(e.g., passageways,
stairwells, elevator landings), provide an enclosure to a height of not
less than 7 feet above the
floor or stair treads as required by ASME A17.1-1996, Rule 1500.1.
The Midway Coop Assn was previously cited for a violation of this
occupational safety and
health standard or its equivalent standard Section 5(a)(1) which was
contained in OSHA
Inspection #303796858, Citation #1, Item #2, issued on 03/19/2001.
29 CFR 1903.19(d)(1) requires certification and documentation that the
abatement of the
above violation is complete.