Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ADM ARKADY

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of ADM ARKADY in 100 S. PANIPLUS, OLATHE, KS 66061 (NAICS 311812). OSHA activity number 305028607.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch ADM Arkady — free Get an email when a new federal OSHA severe-injury report for ADM Arkady is published. One employer, no account, unsubscribe in one click.
Establishment
ADM ARKADY
Site address
100 S. PANIPLUS
City
OLATHE
State
KS
ZIP
66061
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Y
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311812
SIC code (legacy)
2051
Employees
100
Ownership type
A

2 citations on file for this inspection.

5(a)(1)

Deleted Serious Gravity 02 5 instances 10 exposed
Issued
Oct 11, 2002
Abate by
Dec 2, 2002
Penalty
Initial $1,300 · Current $1,300
Section 5(a)1 of the Occupational Safety and Health Act of 1970: The
employer did not furnish
employment and a place of employment which were free from recognized
hazards
that were
causing or likely to cause death or serious physical harm to employees in
that employees were
exposed to crushing hazards from steel shelving units and/or its contents:
(a)At the facility employee(s) working in the warehouse where steel
shelving units had not
been periodically inspected for corrosion, structural damage, or
overloading.  Column
legs C6, C8, G3, and G4 were damaged with pallets of product still in the
storage racks,
thus exposing employee(s) to physical injuries.
(b)At the facility employee(s) working in the warehouse where steel
shelving units had been
modified without the consent of the rack manufacturer.  Column legs E8 and
H13 had
been modified and had not been inspected for structural integrity, thus
exposing
employee(s) to physical injuries.
AMONG OTHER METHODS, ONE FEASIBLE AND ACCEPTABLE METHOD TO
CORRECT THIS HAZARD IS THE FOLLOWING:
Develop and implement a structural integrity program to periodically
inspect storage racks as
recommended by the Rack Manufacturers Institute specifications for the
Design, Testing, and
Utilization of Industrial Steel Storage Racks 1997 Edition, Section 1.4.1.
29 CFR 1903.19(d)(1) requires certification and documentation that the
abatement of the
above violation is complete.
Recent events (2)
  • — I (S) $1300.00
  • — Z (S) $1300.00

1910.176 B

Serious Gravity 02 3 instances 10 exposed
Issued
Oct 11, 2002
Abate by
Oct 31, 2002
Penalty
Initial $1,300 · Current $1,300
Recent events (2)
  • — I (S) $1300.00
  • — Z (S) $1300.00