Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: OWENS CORNING FOAM INSULATION, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of OWENS CORNING FOAM INSULATION, LLC in 2710 LAUDE DRIVE, ROCKFORD, IL 61108 (NAICS 326140). OSHA activity number 305157901.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Owens Corning Foam Insulation, LLC — free Get an email when a new federal OSHA severe-injury report for Owens Corning Foam Insulation, LLC is published. One employer, no account, unsubscribe in one click.
Site address
2710 LAUDE DRIVE
City
ROCKFORD
State
IL
ZIP
61108
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326140
SIC code (legacy)
3086
Employees
73
Ownership type
A

1 citation on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 3 exposed
Issued
Jan 10, 2003
Abate by
Jan 15, 2003
Penalty
Initial $5,000 · Current $2,500 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not furnish
a place of employment that was free from recognized hazards that were
likely to cause death or
serious physical harm to employees in that employees were not provided and
trained on a safe
working procedure to prevent exposure to explosion hazards while
performing maintenance
activities.
December 26, 2002:  Employees, performing maintenance on extrusion line
#1,  received 1st,
2nd and 3rd degree burns to the head and face after a build up of pressure
caused the connection
point between the secondary extruder and dynamic cooler to rupture,
spraying flaming
polystyrene over the immediate work area.  Employees were not provided and
trained on a safe
working procedure that would have prevented the accident.
Among feasible means of abatement would be to comply with the requirements
of ANSI/SPI
B151.7-1996, Plastics Extrusion Machines - Requirements for the
Manufacture,
Care, and Use.
CORRECTED DURING INSPECTION
Recent events (2)
  • — I (S) $2500.00
  • — Z (S) $5000.00

View Owens Corning Foam Insulation, LLC's full OSHA safety record →