ROCKFORD, IL —
OSHA Inspection: OWENS CORNING FOAM INSULATION, LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of OWENS CORNING FOAM INSULATION, LLC in 2710 LAUDE DRIVE, ROCKFORD, IL 61108 (NAICS 326140). OSHA activity number 305157901.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- OWENS CORNING FOAM INSULATION, LLC
- Site address
- 2710 LAUDE DRIVE
- City
- ROCKFORD
- State
- IL
- ZIP
- 61108
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326140
- SIC code (legacy)
- 3086
- Employees
- 73
- Ownership type
- A
Citations
1 citation on file for this inspection.
5(a)(1)
- Issued
- Jan 10, 2003
- Abate by
- Jan 15, 2003
- Penalty
- Initial $5,000 · Current $2,500 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish a place of employment that was free from recognized hazards that were likely to cause death or serious physical harm to employees in that employees were not provided and trained on a safe working procedure to prevent exposure to explosion hazards while performing maintenance activities. December 26, 2002: Employees, performing maintenance on extrusion line #1, received 1st, 2nd and 3rd degree burns to the head and face after a build up of pressure caused the connection point between the secondary extruder and dynamic cooler to rupture, spraying flaming polystyrene over the immediate work area. Employees were not provided and trained on a safe working procedure that would have prevented the accident. Among feasible means of abatement would be to comply with the requirements of ANSI/SPI B151.7-1996, Plastics Extrusion Machines - Requirements for the Manufacture, Care, and Use. CORRECTED DURING INSPECTION
Recent events (2)
- — I (S) $2500.00
- — Z (S) $5000.00
More inspections at Owens Corning Foam Insulation, LLC
View Owens Corning Foam Insulation, LLC's full OSHA safety record →
More inspections in this industry (NAICS 326140)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 305157901.