Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CHAD SUPPLY, INC. DIV. OF HUGHES SUPPLY

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of CHAD SUPPLY, INC. DIV. OF HUGHES SUPPLY in 9707 WILLIAMS ROAD, THONOTOSASSA, FL 33592 (NAICS 000000). OSHA activity number 305224552.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Chad Supply, INC. DIV. of Hughes Supply — free Get an email when a new federal OSHA severe-injury report for Chad Supply, INC. DIV. of Hughes Supply is published. One employer, no account, unsubscribe in one click.
Site address
9707 WILLIAMS ROAD
City
THONOTOSASSA
State
FL
ZIP
33592
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
000000
SIC code (legacy)
4226
Employees
125
Ownership type
A

5 citations on file for this inspection.

5(a)(1)

Deleted Serious Gravity 01 1 instance
Issued
Aug 30, 2002
Abate by
Oct 2, 2002
Penalty
Initial $975 · Current $975
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:
The employer did not furnish employment and a place of employment which
were free from
recognized hazards that were causing or likely to cause death or serious
physical harm to
employees in that employees working where there was insufficient lighting
were exposed to the
potential hazards of contacting acids and corrosives from leaking or
spilled hazardous chemicals:
a)  Warehouse - Lighting in the chemical aisle was measured with a light
meter at 3 to
10 foot candles of light where hazardous chemicals were stored, such as,
but not limited
to muriatic acid, sulfuric acid and corrosives such as Alki Foam and Pool
Cleaner, on
or about 5/7/02.
Among other methods, one feasible and acceptable abatement method to
correct this
hazard is to install lighting which is in accordance with ANSI A11.l 1973
Industrial
Lighting, Table 1, which lists the level of illumination currently
recommended for
storage rooms or warehouses as:  rough bulky - 10 foot-candles; medium -
20 foot-
candles; and fine - 50 foot-candles; and under Materials Handling, picking
stock - 30
foot-candles.
ABATEMENT VERIFICATION REQUIREDTION
Recent events (2)
  • — I (S) $975.00
  • — Z (S) $975.00

1910.151 C

Other-than-serious Gravity 02 1 instance 125 exposed
Issued
Aug 30, 2002
Abate by
Sep 12, 2002
Penalty
Initial $1,300 · Current $625 Reduced
Recent events (2)
  • — I (O) $625.00
  • — Z (S) $1300.00

1910.303 G02 I

Serious Gravity 01 2 instances
Issued
Aug 30, 2002
Abate by
Sep 12, 2002
Penalty
Initial $975 · Current $975
Recent events (2)
  • — I (S) $975.00
  • — Z (S) $975.00

1910.305 B02

Serious Gravity 01 1 instance 120 exposed
Issued
Aug 30, 2002
Abate by
Sep 5, 2002
Recent events (2)
  • — I (S)
  • — Z (S)

1910.1200 H

Other-than-serious Gravity 01 1 instance 125 exposed
Issued
Aug 30, 2002
Abate by
Oct 19, 2002
Penalty
Initial $975 · Current $700 Reduced
Recent events (2)
  • — I (O) $700.00
  • — Z (S) $975.00

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 305224552.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.