THONOTOSASSA, FL —
OSHA Inspection: CHAD SUPPLY, INC. DIV. OF HUGHES SUPPLY
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of CHAD SUPPLY, INC. DIV. OF HUGHES SUPPLY in 9707 WILLIAMS ROAD, THONOTOSASSA, FL 33592 (NAICS 000000). OSHA activity number 305224552.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CHAD SUPPLY, INC. DIV. OF HUGHES SUPPLY
- Site address
- 9707 WILLIAMS ROAD
- City
- THONOTOSASSA
- State
- FL
- ZIP
- 33592
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 4226
- Employees
- 125
- Ownership type
- A
Citations
5 citations on file for this inspection.
5(a)(1)
- Issued
- Aug 30, 2002
- Abate by
- Oct 2, 2002
- Penalty
- Initial $975 · Current $975
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees working where there was insufficient lighting were exposed to the potential hazards of contacting acids and corrosives from leaking or spilled hazardous chemicals: a) Warehouse - Lighting in the chemical aisle was measured with a light meter at 3 to 10 foot candles of light where hazardous chemicals were stored, such as, but not limited to muriatic acid, sulfuric acid and corrosives such as Alki Foam and Pool Cleaner, on or about 5/7/02. Among other methods, one feasible and acceptable abatement method to correct this hazard is to install lighting which is in accordance with ANSI A11.l 1973 Industrial Lighting, Table 1, which lists the level of illumination currently recommended for storage rooms or warehouses as: rough bulky - 10 foot-candles; medium - 20 foot- candles; and fine - 50 foot-candles; and under Materials Handling, picking stock - 30 foot-candles. ABATEMENT VERIFICATION REQUIREDTION
Recent events (2)
- — I (S) $975.00
- — Z (S) $975.00
1910.151 C
- Issued
- Aug 30, 2002
- Abate by
- Sep 12, 2002
- Penalty
- Initial $1,300 · Current $625 Reduced
Recent events (2)
- — I (O) $625.00
- — Z (S) $1300.00
1910.303 G02 I
- Issued
- Aug 30, 2002
- Abate by
- Sep 12, 2002
- Penalty
- Initial $975 · Current $975
Recent events (2)
- — I (S) $975.00
- — Z (S) $975.00
1910.305 B02
- Issued
- Aug 30, 2002
- Abate by
- Sep 5, 2002
Recent events (2)
- — I (S)
- — Z (S)
1910.1200 H
- Issued
- Aug 30, 2002
- Abate by
- Oct 19, 2002
- Penalty
- Initial $975 · Current $700 Reduced
Recent events (2)
- — I (O) $700.00
- — Z (S) $975.00
More inspections in this industry (NAICS 000000)